PRIMERGY RX200 S2 User’s Guide
Inst
allin
g I
nte
rn
al O
pti
ons
7
5
Install a new internal hard disk unit or a dummy unit.
"7.7.3 How to Install an Internal Hard Disk Unit" (pg.193)
■
Replacing the Failed Internal Hard Disk Unit
When an array system (RAID1) is configured with the onboard SCSI array controller on this server, a
failed hard disk unit can be replaced and restoration can be performed without turning off the server and
peripheral devices (hot swappable/hot pluggable).
For details on the array system, refer to "Onboard SCSI RAID User's Guide".
The following is an outline of the procedure for replacing a failed internal hard disk unit.
1
Check the hard disk unit failure LED on each bay.
2
Touch a metal part of the server to discharge static electricity.
3
Move the handle on the failed hard disk unit up and pull it a little towards you.
4
Wait for approximately 60 seconds (until the hard disk stops rotating) and pull
out the failed hard disk unit.
5
Install a new internal hard disk unit.
6
Rebuild the new internal hard disk unit.
For the rebuild procedure, refer to "Onboard SCSI RAID User's Guide".
Содержание PRIMERGY RX200 S2
Страница 6: ...6 ...
Страница 38: ...38 Chapter 1 Overview ...
Страница 52: ...52 Chapter 2 Checking before OS Installation ...
Страница 108: ...108 Chapter 3 OS Installation Using ServerStart ...
Страница 126: ...126 Chapter 4 Manual OS Installation ...
Страница 158: ...158 Chapter 5 Operations after OS Installation ...
Страница 204: ...204 Chapter 7 Installing Internal Options ...
Страница 246: ...246 Chapter 8 Hardware Configuration Utilities ...
Страница 302: ...302 D Recycling ...