4.4
Getting access to the component
CAUTION
▶
Only for non-hot plug components:
●
Before removing or attaching covers, turn off the server, all
peripheral devices, and any other connected devices.
●
Because there is a risk of electric shock or damage, please
disconnect all power cords from the outlet.
▶
The top cover must be replaced as soon as possible for purposes
of cooling, to comply with EMC regulations (regulations regarding
electromagnetic compatibility) and to prevent fires.
▶
"Important information" on page 29
.
4.4.1
Extending the server out of the rack
CAUTION
▶
Use the anti-tilt plate to prevent the rack from tipping when
installing the rack. Pulling the server out of the rack without having
installed the anti-tilt plate may cause the rack to tip over.
▶
Be careful not to pinch fingers or clothes when sliding out the
server or pushing it back. Failure to do so may cause injury.
▶
"Important information" on page 29
.
▶
Remove all remaining external cables from the I/O panel and expansion
cards.
▶
If you are not using a cable management arm (CMA kit), ensure that the rear
cables are long enough not to be strained or damaged when extending the
server out of the rack.
Basic hardware procedures
48
Upgrade and Maintenance Manual
RX1330 M4
Содержание PRIMERGY RX1330 M4
Страница 16: ...17 Appendix B 365 17 1 Supplied documents 365 Content Upgrade and Maintenance Manual RX1330 M4 ...
Страница 98: ...Basic software procedures 98 Upgrade and Maintenance Manual RX1330 M4 ...
Страница 176: ...Hard disk drive HDD solid state drive SSD 176 Upgrade and Maintenance Manual RX1330 M4 ...
Страница 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M4 ...
Страница 364: ...Appendix A 364 Upgrade and Maintenance Manual RX1330 M4 ...
Страница 366: ...FUJITSU Server PRIMERGY RX1330 M4 Reference Manual Reference Manual English Cable Plan for April 2022 ...
Страница 394: ...29 RX1330 M4 Dual microSD 64GB Enterprise Cable Plan C57 System Board ROC USB 1 Dual microSD 64GB Enterprise CON1 ...
Страница 398: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...