16.4
Minimum startup configuration
Field Replaceable Units
(FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
Notes
System board
no TPM, UFM, or expansion cards installed
CPU with heat sink
1 memory module
installed in DIMM slot 1A
Front panel module
PSU
Table 4: Minimum startup configuration - components
Cable
Notes
Front panel cable
Power cable
Table 5: Minimum startup configuration - cables
▶
"Shutting down the server" on page 45
▶
"Disconnecting the power cord" on page 46
▶
Take the system down to its minimum startup configuration.
▶
"Connecting the power cord" on page 56
.
▶
Connect a display to the server.
▶
"Switching on the server" on page 58
.
Appendix A
362
Upgrade and Maintenance Manual
RX1330 M4
Содержание PRIMERGY RX1330 M4
Страница 16: ...17 Appendix B 365 17 1 Supplied documents 365 Content Upgrade and Maintenance Manual RX1330 M4 ...
Страница 98: ...Basic software procedures 98 Upgrade and Maintenance Manual RX1330 M4 ...
Страница 176: ...Hard disk drive HDD solid state drive SSD 176 Upgrade and Maintenance Manual RX1330 M4 ...
Страница 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M4 ...
Страница 364: ...Appendix A 364 Upgrade and Maintenance Manual RX1330 M4 ...
Страница 366: ...FUJITSU Server PRIMERGY RX1330 M4 Reference Manual Reference Manual English Cable Plan for April 2022 ...
Страница 394: ...29 RX1330 M4 Dual microSD 64GB Enterprise Cable Plan C57 System Board ROC USB 1 Dual microSD 64GB Enterprise CON1 ...
Страница 398: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...