Preparation for Use/Operation
Switching the Server ON/OFF
Server in standby mode
Power-on indicator flashes green. The ON/OFF button is being pressed.
System fans speed slows down due to a IPMI signal.
Ê
Shut down all RGB applications.
Ê
Press any button to return to normal operation.
Other ON/OFF possibilities
In addition to the ON/OFF button, the server can be switched ON and OFF in
the following ways:
–
Specified switch-On time/switch-OFF time
The server is switched ON or OFF at a time specified in the
ServerView
program.
–
Ring indicator
The server is switched ON via an internal or external modem.
–
Wakeup On LAN (WOL)
The server is switched ON by a command via the LAN.
–
After power failure
The server automatically switches ON following a power failure (depending
of the settings in the BIOS).
–
Power override function
The system may be switched OFF “unconditionally” by pressing the ON/OFF
button for about 4 to 5 seconds.
V
CAUTION!
Data loss may occur!
–
IPMI
The server is switched ON by an IPMI console (via the serial COM1 port or
via the LAN port 1). If necessary, the COM1 port must first be enabled in the
BIOS Setup
, as it is disabled by default.