Conversion procedure
15
Updating the Chassis ID
After installing the server to the rack, update the chassis ID as follows:
1
Check that no media has been left in the floppy disk drive, CD-ROM,
etc.
2
Turn on the display and any attached peripherals.
3
Insert the "Hardware Configuration Tool Boot Floppy" provided with the
server in the floppy disk drive and turn on the server.
The menu will appear.
4
Select "Server Management Tool" from menu and press [Enter].
After appearing the DOS prompt, remove the "Hardware Configuration Tool Boot
Floppy".
5
Insert the "Server Management Tools" disk provided with the server into
the floppy disk drive and type the following commands:
A:\>WRTID.BAT F200R.ini
[Enter]
The following message appears when properly executed.
Normal End
6
Turn off the server.
Before rebooting the system from the ServerStart CD or "Hard-
ware Configuration Tool Floppy", first check that the ServerView
"OS Boot Monitoring" function has been disabled (default setting
is "Disabled").
If the system is started with the "OS Boot Monitoring" function
enabled, the server is liable to automatically shutdown and/or
reboot and/or perform other unexpected operations.
If the "OS Boot Monitoring" function is needed, it should be reset
to enabled before resuming normal server operation.
See the "Server View User’s Guide" on ServerVIew CD-ROM for
more ServerView information.
A "Hardware Configuration Tool Boot Floppy" may be created
using the ServerStart CD.
For details on how to create, refer to "PRIMERGY F200 Supple-
ment".
Содержание PRIMERGY PG-R1CK6
Страница 7: ...vi ...
Страница 9: ...viii ...
Страница 11: ...x ...
Страница 13: ...2 本製品の梱包物 ブラケット C 1 2 M3 ネジ 6 M4 バインドネジ 4 M4 タップタイトネジ 4 M5 ネジ 1 8 M6 ネジ 1 4 部品 名称 数量 確認 ...
Страница 15: ...4 本製品の梱包物 ...
Страница 43: ...32 付録 ...
Страница 49: ...vi ...
Страница 51: ...viii ...
Страница 55: ...4 Ensuring the package ...
Страница 83: ...32 Conversion procedure ...
Страница 85: ...34 ...