GX2460 M1
Upgrade and Maintenance Manual
91
Hard disk drive (HDD) and solid state drive (SSD)
7.3.4
Replacing a 2.5-inch HDD/SSD module
V
CAUTION!
●
Only remove an HDD/SSD module during operation if the drive is not
currently being accessed. Observe the indicators for the
corresponding HDD/SSD modules, see section
hot-plug HDD/SSD module" on page 229
.
●
An HDD/SSD module can be replaced while the system is in
operation.
RAID configuration with a RAID controller:
Modular Host Bus Adapter with "Integrated RAID" (IR). RAID levels 0
and 1 are supported for internal HDD configurations.
– Modular RAID 0/1 controller with "MegaRAID functionality"
(integrated MegaRAID). RAID levels 0, 1,10,5 and 50 are
supported for internal HDD configurations.
– Modular RAID 5/6 controller with "MegaRAID functionality"
(MegaRAID). RAID levels 0, 1, 10, 5, 50, 6 and 60 are supported
for internal HDD configurations. As an option, a flash backup unit
(FBU) can save the memory content even if the power fails.
Cache memory size of up to 8 GB is available.
RAID configuration without a RAID controller:
Please follow the instruction of each software e.g. VSAN, Storage
Spaces, and Storage Spaces Direct, provided separately to use the
software RAID function of OS or Hypervisor.
●
All HDD/SSD modules (drives) must be uniquely identified so that
they can be installed again in their original bays later. If this is not
done, existing data can be lost.
7.3.4.1
Preliminary steps
Ê
"Locating the defective server" on page 39
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools:
tool-less
Содержание PRIMERGY GX2460 M1
Страница 16: ...16 Upgrade and Maintenance Manual GX2460 M1 Contents ...
Страница 26: ...26 Upgrade and Maintenance Manual GX2460 M1 Before you start ...
Страница 56: ...56 Upgrade and Maintenance Manual GX2460 M1 Basic hardware procedures ...
Страница 78: ...78 Upgrade and Maintenance Manual GX2460 M1 Power supply unit PSU ...
Страница 96: ...96 Upgrade and Maintenance Manual GX2460 M1 Hard disk drive HDD and solid state drive SSD ...
Страница 108: ...108 Upgrade and Maintenance Manual GX2460 M1 Fans ...
Страница 143: ...GX2460 M1 Upgrade and Maintenance Manual 143 Expansion cards and riser modules Ê Switching on the server on page 54 ...
Страница 153: ...GX2460 M1 Upgrade and Maintenance Manual 153 Expansion cards and riser modules Ê Switching on the server on page 54 ...
Страница 158: ...158 Upgrade and Maintenance Manual GX2460 M1 Expansion cards and riser modules ...
Страница 225: ...GX2460 M1 Upgrade and Maintenance Manual 225 Appendix A Figure 183 Indicators on the system board ...
Страница 242: ...242 Upgrade and Maintenance Manual GX2460 M1 Appendix A ...
Страница 244: ...244 Upgrade and Maintenance Manual GX2460 M1 Appendix B ...
Страница 250: ...RAID Card RAID Card HDD Back Plane 411T61300070 SAS MLC1 SAS MLC2 SATA 0 3 SATA 4 7 C17 C17 ...