98
Upgrade and Maintenance Manual
CX400 M4
Hard disk drives (HDD), solid state drives (SSD) and 2.5-inch PCIe-SSD
7.3
Removing 2.5-inch HDD/SSD modules
7.3.1
Preliminary steps
Perform the following procedures:
Ê
Ensure that the HDD/SSD module to be removed is not combined into a
RAID array. If the drive is part of a RAID array, you first need to delete the
array using ServerView RAID Manager.
V
CAUTION!
All data on all HDDs/SSDs in the array will be lost when deleting the
array! Be sure to back up your data before deleting a RAID array.
I
For further information, please refer to the "ServerView Suite RAID
Management" user guide, available online at
.
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools:
Preliminary and concluding steps: tool-less
Main steps: tool-less