BX920 S4
Upgrade and Maintenance Manual
75
Basic software procedures
5.2
Completing the maintenance task
5.2.1
Updating or recovering the system board BIOS and
iRMC
After replacing the server blade, a processor or memory modules, it is essential
to upgrade the BIOS and iRMC to the latest version. The latest BIOS and iRMC
versions are available from the Fujitsu support internet pages at:
http://ts.fujitsu.com/support/
(EMEA market)
http://jp.fujitsu.com/platform/server/primergy/downloads/
(Japanese market)
I
Fujitsu does not assume responsibility for any damage done to the
server or for the loss of any data resulting from BIOS updates.
5.2.1.1
Updating or recovering the system board BIOS
TFTP update procedure
Ê
Ensure that the server blade has been shut down as described in section
"Shutting down the server blade" on page 53
.
Ê
Log in to the management blade web interface.
Ê
Open the
Information / Operation – Operation – Firmware Update
menu.
Ê
Open the
Server Blade
tab.
Ê
In the
Server Blade to be Updated
box select the desired server.
Ê
In the
Update settings
box select the update firmware (BIOS).
Ê
In the
Update settings
box enter the TFTP IPv4 or IPv6 address of the TFTP
server and the pathname of the TFTP firmware file.
I
For more detailed information, refer to the
Help – On Page
function of
the management blade web interface.
Ê
Click the
Apply
button to start the update process.
The status column in the
Server Blade to be Updated
box provides information
on the update progress.