PRIMERGY BX620 S4 Server Blade User’s Guide
Setting the time synchronization function with the Management Blade
To set the time synchronization function with the Management Blade, select "Sync RTC with Mgnt.
Blade" in the [Main] menu on the BIOS Setup Utility, and specify the time synchronization function.
Using an USB CD/DVD drive (change of device priority sequence)
When using the USB CD/DVD drive, change the device priority sequence in the [Boot] menu of the
BIOS Setup Utility.
For more details about changing the boot drive, refer to "8.2.15 Boot Device Priority Submenu"
Booting the Server Blade with PXE
Before Booting the Server Blade with PXE, use the following procedures to enable network startup
(PXE). In addition, check the MAC address.
When booting the Server Blade with PXE, turn on the Server Blade power one minute or more after the
main power of the Chassis was turned on. Turning on the Server Blade power just after the main
power was turned on may cause PXE not to boot due to the Switch Blade not having been started.
The PXE boot function is not available for the LAN port of the 1 Gbit/s Ethernet I/O Module.
1
Take the following steps in the BIOS Setup Utility.
Set PXE (IBA CE slot nnnn v) to the highest level in the boot priority sequence.
For more details about changing the boot drive, refer to "8.2.15 Boot Device Priority Submenu"
The boot priority sequence can be changed from Web UI or CLI for the Management Blade.
Refer to "BX600 Management Blade Hardware Guide".
2
Check the MAC address.
After BIOS setup, start up the server from the network.
After POST was completed, the MAC address is displayed as shown below.
3
Turn off the server.
You can confirm that the server is turned off using "Deployment Parameter" for Web UI and
CLI, and "Server Blade MAC Address Table" for CLI of the Management Blades. For details,
refer to "BX600 Management Blade Hardware Guide".
1st Boot Device [Y-E USB-FDU]
2nd Boot Device [CENERIC CDR****]
3rd Boot Device [#520 ID00 LUN0 ***] (When an expansion card slot
module is not installed)
4th Boot Device [IBA CE Slot **** v]
5th Boot Device [IBA CE Slot **** v]
CLIENT MAC ADDR: ** ** ** ** ** **
Содержание PRIMERGY BX620 S4
Страница 8: ...8 ...
Страница 14: ...14 ...
Страница 46: ...46 Chapter 2 Checking before OS Installation ...
Страница 98: ...98 Chapter 4 Manual OS Installation ...
Страница 104: ...104 Chapter 5 Operations after OS Installation 5 Click the Advanced tab For Windows Server 2008 For Windows Server 2003 ...
Страница 170: ...170 Chapter 6 High Reliability Tools ...
Страница 272: ...272 Appendix ...