190
Chapter 7 Installing Internal Options
Notes when adding an Expansion Card Slot Module
When using an onboard array controller in this Server Blade and replacing the SAS module that is
installed standardly with an Expansion Card Slot Module (PG-CS103/PG-CS104), initialization of the
logical drive of the array controller may be performed after replacing the module.
This is due to the fact that information about data consistency, which is used to record whether write data
is correctly written to the internal hard disk unit in the past, is stored on the standard SAS module.
When the information is lost by replacing the module, initialization is automatically executed to ensure
data consistency.
For details about initialization, refer to the manual in the Array controller Document & Tool CD.
7.5.3 How to Install an Expansion Card
To install the PCI-X and PCI-Express cards, perform the same procedures.
1
Turn off the Server Blade.
→
"3.3 Turning Off the Server" in "BX600 S3 Blade Server System Unit Hardware Guide"
2
Touch the metal part of the Chassis to discharge static electricity.
3
Remove the Server Blade to install an expansion card slot module in, from the
Chassis.
→
"4.2 Installing Server Blades/Storage Blades" in "BX600 S3 Blade Server System Unit
Hardware Guide"
4
Remove the top cover.
"7.2 Removing and Attaching the Top Cover" (pg.174)
5
Remove the standard SAS module from the Server Blade.
Remove the screw, and remove the standard SAS module.
Screw
SAS module
Содержание PRIMERGY BX620 S4
Страница 8: ...8 ...
Страница 14: ...14 ...
Страница 46: ...46 Chapter 2 Checking before OS Installation ...
Страница 98: ...98 Chapter 4 Manual OS Installation ...
Страница 104: ...104 Chapter 5 Operations after OS Installation 5 Click the Advanced tab For Windows Server 2008 For Windows Server 2003 ...
Страница 170: ...170 Chapter 6 High Reliability Tools ...
Страница 272: ...272 Appendix ...