PRIMERGY BX600 S3 Blade Server System Unit Hardware Guide
6.5 Non-durable Components
This Chassis monitors the status of power supply unit (PSU), sending notification
when they need to be replaced. Management Blade performs monitoring and
notifying.
The following function is available.
• By this, the Chassis can evade shutdowns due to failure of these component.
The following are the non-durable components.
• PSU
• Dummy PSU
■
Management Blade Settings for Non-durable Components
• Perform Management Blade settings for non-durable components before operating the server. For
details, refer to "BX600 Management Blade Hardware Guide".
• If you use this Chassis without performing Management Blade settings, no notification will be sent,
which informs when a component has reached the near-end of its lifetime. This will result in
unnecessary system shutdowns.
• Non-durable components are supposed to be replaced in the periodical maintenance performed after
these messages appear. These parts can be continuously used for approximately one year after the
message.
6.5.1 Component Lifetime Information Browse/Setting
Menu
The running hours and lifetime of the non-durable components of this Chassis can be displayed using
the Web UI of the Management Blades.
The following items must be checked or set in the Web UI ([System Property] - [Environ./Maintenance]
- [Power Supply]) of the Management Blades when commencing use of this Chassis and when such a
component is being replaced. For details about display methods and operations, refer to "BX600
Management Blade Hardware Guide".
• Installation Date
Enter the installation/replacement date of the PSU and dummy PSU in this Chassis.
• Life Time
Displays the lifetime of the system fan unit, PSU and dummy PSU in this Chassis. It is measured in
units of hours (hrs). If running time exceeds this value, event log is recorded/notified.