4-100
C122-E001-10EN
CHAPTER 4 Work Required After Operating System Installation
Information to be monitored and processing to be performed
z
Information to be monitored
S.M.A.R.T. performs predictive monitoring for the information types below and
reports when the threshold defined for each of them in S.M.A.R.T. is exceeded.
The threshold for each item depends on the type of disk of each vendor.
- Temperature
- Read error rate
- Write error rate
- Seek error rate
- Spin-up time
- Number of remaining alternate sectors
After monitoring is set, the system periodically (at about six-hour intervals) polls
S.M.A.R.T. on each disk to check for predictive detection.
z
Processing performed at detection of a predictive sign of error
- Blinks the Fault LED on the relevant disk by repeating a cycle of "four quick
pause"
- Outputs information posted from S.M.A.R.T. to SYSLOG and reports it
(REMCS/e-mail)
Procedure
1
Click [Partition]
→
[Partition#x]
→
[PSA]
→
[Setup]
→
[S.M.A.R.T.].
The [S.M.A.R.T.] window is displayed.
Figure 4.48 [S.M.A.R.T.] window
2
Select [Enable] or [Disable] and click the [Apply] button.
Item
Description
S.M.A.R.T. Monitoring
• [Enable]: Enables S.M.A.R.T. monitoring.
• [Disable]: Disables S.M.A.R.T. monitoring.
Default: [Enable]
Содержание PRIMEQUEST 400 Series
Страница 1: ...C122 E001 10EN Front Cover INSTALLATION MANUAL ...
Страница 2: ......
Страница 18: ...x C122 E001 10EN NOTE ON SAFETY Extended Power Cabinet ...
Страница 19: ...C122 E001 10EN xi NOTE ON SAFETY Extended I O Cabinet ...
Страница 20: ...xii C122 E001 10EN NOTE ON SAFETY PCI_Box ...
Страница 21: ...C122 E001 10EN xiii NOTE ON SAFETY PRIMEQUEST 520A 520 420 Main unit ...
Страница 22: ......
Страница 24: ......
Страница 42: ......
Страница 46: ......
Страница 122: ......
Страница 140: ...3 18 C122 E001 10EN CHAPTER 3 Operating System Installation The installation procedure is as follows ...
Страница 150: ...3 28 C122 E001 10EN CHAPTER 3 Operating System Installation The installation procedure is as follows ...
Страница 186: ......
Страница 354: ......
Страница 356: ......
Страница 378: ...C 4 C122 E001 10EN Appendix C Power Control Figure C 3 Circuit breaker locations Extended I O Cabinet Circuit breaker ...
Страница 394: ......
Страница 428: ......
Страница 445: ......
Страница 446: ...Back Cover ...