C122-E001-10EN
4-69
4.5 PSA Installation (Windows Server 2003) (PRIMEQUEST 580A/540A/580/540/480/440)
4.5.1
Checking the management LAN settings
This section describes how to check the management LAN settings.
For communication of PSA with the MMB via the management LAN, the NIC
connected to the management LAN on the partition side must be active.
Note:
If you perform batch installation using the batch installer included in the
High-Reliability Tools, configure the management LAN after the batch
installation is completed.
(1)
Verifying the NIC for the management LAN
In Device Manager, display the properties of the network adapters (Intel PRO/100 VE
Network Connection and Intel PRO/100 M Network Connection) assigned to the
management LAN, and check the settings in [Location] on the [General] tab.
Connect the network adapters for the management LAN to MMB#0 and MMB#1 as
follows:
- MMB#0: PCI Bus 1, Device 8, Function 0
- MMB#1: PCI Bus 1, Device 0, Function 0
Use the teaming function of Intel PROSet to configure the above network adapters for
duplicated communication with the management LAN.
For Intel PROSet teaming, specify the IP addresses of the devices for the management
LAN that are configured for duplicated communication.
(2)
Configuring the two network adapters for the management LAN so that
the adapters are duplicated
Use the teaming function of Intel PROSet to configure the network adapter for the
management LAN to guarantee management LAN operation for duplicated
communication.
Install Intel PROSet beforehand.
Note:
z
Change the VLAN setting of the MMB management LAN hub to "VLAN
Mode." (For details, see
2.2.4.5, Setting a management LAN hub.
)
z
The Spanning Tree Protocol (STP) function of the switch connected to the
user port (management LAN) of the MMB must be disabled.
z
To make settings through a connection to a remote desktop, a console
session connection must be established. Establish this type of connection
according to the following procedure:
Содержание PRIMEQUEST 400 Series
Страница 1: ...C122 E001 10EN Front Cover INSTALLATION MANUAL ...
Страница 2: ......
Страница 18: ...x C122 E001 10EN NOTE ON SAFETY Extended Power Cabinet ...
Страница 19: ...C122 E001 10EN xi NOTE ON SAFETY Extended I O Cabinet ...
Страница 20: ...xii C122 E001 10EN NOTE ON SAFETY PCI_Box ...
Страница 21: ...C122 E001 10EN xiii NOTE ON SAFETY PRIMEQUEST 520A 520 420 Main unit ...
Страница 22: ......
Страница 24: ......
Страница 42: ......
Страница 46: ......
Страница 122: ......
Страница 140: ...3 18 C122 E001 10EN CHAPTER 3 Operating System Installation The installation procedure is as follows ...
Страница 150: ...3 28 C122 E001 10EN CHAPTER 3 Operating System Installation The installation procedure is as follows ...
Страница 186: ......
Страница 354: ......
Страница 356: ......
Страница 378: ...C 4 C122 E001 10EN Appendix C Power Control Figure C 3 Circuit breaker locations Extended I O Cabinet Circuit breaker ...
Страница 394: ......
Страница 428: ......
Страница 445: ......
Страница 446: ...Back Cover ...