FIGURE 3.17 [System Information] window (example)
2. Enter a name in [System Name].
3. Click the [Apply] button.
3.3.12
Setting the date and time
Set the MMB date and time. Configure NTP (to use an NTP server) as needed.
The field engineer may have already done this. If so, proceed to the next setting item unless you need to change a
setting.
For details on how to back up the specified information, see
3.5 Saving Configuration Information
.
Remarks
The MMB provides the NTP client function. The NTP client function of the MMB adjusts time by using another
NTP server as reference. For stable NTP operation, specify multiple NTP servers (at least three servers in RHEL)
from each NTP client.
Operations in the [Date/Time] window
1. Click [Network Configuration] - [Date/Time].
>> The [Date/Time] window appears. For details on the [Date/Time] window, see 1.5.1 [Date/Time]
window in the
PRIMEQUEST 1000 Series Tool Reference
(C122-E110EN).
PRIMEQUEST 1000 Series Installation Manual
CHAPTER 3 Work before Operating System Installation
40
C122-E107-09EN
Содержание PRIMEQUEST 1000 Series
Страница 1: ...C122 E107 09EN FUJITSU Server PRIMEQUEST 1000 Series Installation Manual ...
Страница 2: ......
Страница 32: ...PRIMEQUEST 1000 Series Installation Manual CHAPTER 1 Installation Overview 4 C122 E107 09EN ...
Страница 44: ...PRIMEQUEST 1000 Series Installation Manual CHAPTER 2 Preparing for Main Unit Installation 16 C122 E107 09EN ...
Страница 260: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX A Lists of Settings Links 232 C122 E107 09EN ...
Страница 284: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation 256 C122 E107 09EN ...
Страница 340: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server Windows 312 C122 E107 09EN ...
Страница 344: ......