>> The submenu area displays the submenu of the selected menu.
2. Select a menu item from the submenu.
>> The content area display in the window corresponds to the selected menu item.
3. Check or set information in the displayed window.
Click the [Apply] button to set information.
Click the [Cancel] button to revert to the settings before input.
Note
The MMB Web-UI may display a confirmation dialog box for process execution or notification dialog box for
process completion. If the MMB Web-UI is running in IE and the dialog box remains displayed for more than two
minutes, the MMB Web-UI connection is terminated. In such cases, log in to the MMB Web-UI again.
3.3.6
Configuring the MMB network
Configure the MMB network. For the items already set at this time, confirm the setting contents. For the items not
set, make the settings.
Set the following IP addresses:
- Virtual IP address used to access the Web-UI
- Physical IP address assigned to the MMB interface ... etc.
For details on how to back up the specified information, see
3.5 Saving Configuration Information
.
Notes
- When the MMB is not duplicated and the PRIMECLUSTER linkage is disabled, the physical IP address
setting for the MMB is not necessary.
- Log in with Administrator privileges to configure the MMB network.
- To change an IP address on the MMB side between PSA and the MMB, change the IP address setting on all
partitions in the same cabinet. For details on how to change the setting, see
6.3.1 Configuring the PSA-to-MMB communication LAN
- If the PSA-to-MMB communication LAN setting is Disable, the PSA Web-UI does not appear. Moreover,
REMCS notifications and e-mail notifications related to PSA (PRIMEQUEST 1800E) or SVS
(PRIMEQUEST 1800E2) are not output.
- If you change a value in [MMB#0 IP Address] or [MMB#1 IP Address] in the [Network Interface] window
and then click the [Apply] button:
The network is suspended and the Web-UI is disconnected to enable the settings. You can connect to the
Web-UI again by selecting the Web-UI menu.
- If you change the virtual IP address:
The MMB Web-UI is disconnected. You need to log in again to use the MMB Web-UI.
Remarks
Once the virtual IP address is set:
Web browsers have access through the virtual IP address of the PRIMEQUEST 1000 series server. They cannot
access the MMB Web-UI through the specified physical IP address of MMB#0 or MMB#1.
The maintenance terminal and REMCS has access through the address specified in [Maintenance IP Address]. You
can specify the address by selecting [Network Configuration] - [Network Interface].
PRIMEQUEST 1000 Series Installation Manual
CHAPTER 3 Work before Operating System Installation
32
C122-E107-09EN
Содержание PRIMEQUEST 1000 Series
Страница 1: ...C122 E107 09EN FUJITSU Server PRIMEQUEST 1000 Series Installation Manual ...
Страница 2: ......
Страница 32: ...PRIMEQUEST 1000 Series Installation Manual CHAPTER 1 Installation Overview 4 C122 E107 09EN ...
Страница 44: ...PRIMEQUEST 1000 Series Installation Manual CHAPTER 2 Preparing for Main Unit Installation 16 C122 E107 09EN ...
Страница 260: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX A Lists of Settings Links 232 C122 E107 09EN ...
Страница 284: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation 256 C122 E107 09EN ...
Страница 340: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server Windows 312 C122 E107 09EN ...
Страница 344: ......