E.2
Notes on VMware 4.x Installation
Install VMware 4.x by following the instructions in the
VMware vSphere 4.x Software Handbook
.
For details on the VMware 4.x information and procedures that you need to know for PRIMEQUEST system
configuration, contact the distributor where you purchased your product, or your sales representative.
Note the following points during VMware 4.x installation.
- To make the network settings for the PRIMEQUEST 1800E, use the steps in
- After completing the installation, press the [Alt] + [F1] keys to log in to the ESX Console.
FIGURE E.1 Completion of VMware 4.x installation
- When VMware 4.x is used, fatal system errors such as a panic are not detected automatically.
Therefore, perform the following procedures after installation and set the Watchdog Timer for detecting such
fatal system errors.
For setting the Watchdog Timer monitoring, use ServerView Operations Manager (V4.92-14 or later).
Note
The setting procedure varies with the version of ServerView Operations Manager (SVOM) being used. Check
the version number, and follow the appropriate procedure below.
When using SVOM 4.92
1. Start ServerView Operations Manager.
2. Select [ServerList].
3. Right-click the target partition in the server list on the left side. Select [Maintenance] - [ASR Properties] from
the displayed menu.
4. Select [Watchdog] in the displayed window.
5. Specify the following for [Software], and click [Apply].
- Check the [Active] check box.
- Select [Continue] for [Action] for cases of abnormal operation.
PRIMEQUEST 1000 Series Installation Manual
APPENDIX E Notes on VMware Installation
262
C122-E107-09EN
Содержание PRIMEQUEST 1000 Series
Страница 1: ...C122 E107 09EN FUJITSU Server PRIMEQUEST 1000 Series Installation Manual ...
Страница 2: ......
Страница 32: ...PRIMEQUEST 1000 Series Installation Manual CHAPTER 1 Installation Overview 4 C122 E107 09EN ...
Страница 44: ...PRIMEQUEST 1000 Series Installation Manual CHAPTER 2 Preparing for Main Unit Installation 16 C122 E107 09EN ...
Страница 260: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX A Lists of Settings Links 232 C122 E107 09EN ...
Страница 284: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation 256 C122 E107 09EN ...
Страница 340: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server Windows 312 C122 E107 09EN ...
Страница 344: ......