- SNMP Service uses UDP port 161 (to receive data from the MMB).
- fjpsawg.exe uses TCP port 24450 (to receive data from the MMB).
- fjpsammbs.exe uses a port to send data to the MMB (TCP port 5000 on the MMB side).
- fjpsammbs.exe uses ICMP as the protocol for the MMB.
Operations
1. Select [Start] - [Administrative Tools] - [Windows Firewall with Advanced Security].
2. The [Windows Firewall with Advanced Security] window appears. Click [Inbound Rules] in the left pane.
The [Inbound Rules] list appears in the center pane.
FIGURE 6.8 Windows Firewall window
3. Select and right-click [SNMP Service (UDP In)] in the [Inbound Rules] list. Then, click [Properties].
The two default profiles for SNMP Service (UDP In) are [Domain] and [Private, Public]. Perform steps 3 to
7 for both profiles.
4. The [SNMP Service (UDP In) Properties] dialog box appears. Click the [General] tab. Then, check the
[Enabled] check box in [General] (checked by default).
PRIMEQUEST 1000 Series Installation Manual
CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E)
169
C122-E107-09EN
Содержание PRIMEQUEST 1000 Series
Страница 1: ...C122 E107 09EN FUJITSU Server PRIMEQUEST 1000 Series Installation Manual ...
Страница 2: ......
Страница 32: ...PRIMEQUEST 1000 Series Installation Manual CHAPTER 1 Installation Overview 4 C122 E107 09EN ...
Страница 44: ...PRIMEQUEST 1000 Series Installation Manual CHAPTER 2 Preparing for Main Unit Installation 16 C122 E107 09EN ...
Страница 260: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX A Lists of Settings Links 232 C122 E107 09EN ...
Страница 284: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation 256 C122 E107 09EN ...
Страница 340: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server Windows 312 C122 E107 09EN ...
Страница 344: ......