# /etc/rc.d/init.d/snmpd restart
After that operation, a Cold Start trap is posted to the trap receiving application at the trap destination. Cold Start
is a standard net-snmp trap.
In the following example, the trap destination is a Linux machine. snmptrapd runs on the Linux machine that is the
trap destination to receive traps. snmptrapd outputs the following message to the system log. Confirm that the Linux
machine received the trap normally.
Aug 17 12:00:53 pq-server snmptrapd[2600]: 2005-08-17 12:00:53 \
pq-server.
fujitsu.com [192.168.0.162](via 192.168.0.162) TRAP, SNMP v1, \
community
public NET-SNMP-MIB::netSnmpAgentOIDs.10 Cold Start Trap (0) \
Uptime: 0:00:00.17
\: This indicates that there is no line feed.
6.2.6
Setting the destinations of traps and e-mail via the MMB
You can set the destinations of traps and e-mail via the MMB by using the MMB Web-UI.
For details on MMB trap destinations, see
. For details on e-mail destinations, see
Remarks
- Make settings only as needed.
- Operations management software (e.g., Systemwalker) needs these settings to manage events by partition.
6.2.7
Setting the management LAN IP address
Set the partition management LAN IP address in PSA. For details on the management LAN, see 1.3 Management
LAN in the
PRIMEQUEST 1000 Series Administration Manual
(C122-E108EN).
Note
Here, set the IP address on the partition instead of the IP address on the MMB.
Edit the /etc/opt/FJSVpsa/usr/ipsetup.conf file.
Example of changing the management LAN IP address
# vi /etc/opt/FJSVpsa/usr/ipsetup.conf
Change the following line.
[NETWORK]
ManagementIP=<management LAN IP address>
Syntax
PRIMEQUEST 1000 Series Installation Manual
CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E)
144
C122-E107-09EN
Содержание PRIMEQUEST 1000 Series
Страница 1: ...C122 E107 09EN FUJITSU Server PRIMEQUEST 1000 Series Installation Manual ...
Страница 2: ......
Страница 32: ...PRIMEQUEST 1000 Series Installation Manual CHAPTER 1 Installation Overview 4 C122 E107 09EN ...
Страница 44: ...PRIMEQUEST 1000 Series Installation Manual CHAPTER 2 Preparing for Main Unit Installation 16 C122 E107 09EN ...
Страница 260: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX A Lists of Settings Links 232 C122 E107 09EN ...
Страница 284: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation 256 C122 E107 09EN ...
Страница 340: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server Windows 312 C122 E107 09EN ...
Страница 344: ......