MMLAN all -- 0.0.0.0/0 0.0.0.0/0
Chain MMLAN (2 references)
target prot opt source destination
ACCEPT udp -- 192.168.0.0/24 192.168.0.1 udp dpts:7000:7100
ACCEPT udp -- 192.168.0.1 192.168.0.0/24 udp spts:7000:7100
ACCEPT udp -- 192.168.0.0/24 192.168.0.1 udp dpt:162
ACCEPT udp -- 192.168.0.1 192.168.0.0/24 udp spt:162
ACCEPT udp -- 192.168.1.5 192.168.0.1 udp dpts:7000:7100
ACCEPT udp -- 192.168.0.1 192.168.1.5 udp spts:7000:7100
ACCEPT udp -- 192.168.1.5 192.168.0.1 udp dpt:162
ACCEPT udp -- 192.168.0.1 192.168.1.5 udp spt:162
7. Save the firewall configuration.
# /sbin/service iptables save
PSA-to-MMB communication LAN interfaces
Open the following ports for use with the PSA-to-MMB communication LAN interfaces.
Usually, the ports are automatically opened during PSA installation.(*)
* In PSA version 2.6 and later, the ports are automatically configured only when PSA is installed from SVIM.
TABLE 6.5 Ports to open for the PSA-to-MMB communication LAN interfaces
Port
Port number
Description
Remarks
snmp port
udp/snmp or 161
For sending and
receiving
web-mmb
communication port
tcp/fj-webgate or 24450 web-mmb communication port
For sending and
receiving
psa-mmb
communication port
tcp/5000 on MMB side Communication using port 5000 on
the MMB side.
The partition acts as the client in this
type of communication, so the
partition uses a dynamic port number
(one of the ports in the range tcp/1025
to 65535).
Under certain circumstances, there is
no need to set port number 5000. One
example is a setting that permits a
connection to be established from the
partition. Another example is a
setting permitting communication
through an established connection
with the partition.
For sending and
receiving
PRIMEQUEST 1000 Series Installation Manual
CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E)
139
C122-E107-09EN
Содержание PRIMEQUEST 1000 Series
Страница 1: ...C122 E107 09EN FUJITSU Server PRIMEQUEST 1000 Series Installation Manual ...
Страница 2: ......
Страница 32: ...PRIMEQUEST 1000 Series Installation Manual CHAPTER 1 Installation Overview 4 C122 E107 09EN ...
Страница 44: ...PRIMEQUEST 1000 Series Installation Manual CHAPTER 2 Preparing for Main Unit Installation 16 C122 E107 09EN ...
Страница 260: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX A Lists of Settings Links 232 C122 E107 09EN ...
Страница 284: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation 256 C122 E107 09EN ...
Страница 340: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server Windows 312 C122 E107 09EN ...
Страница 344: ......