Technical data
Port assignment
66
A26391-K82-Z101-3-7619
Parallel port
1
13
25
14
The parallel port supports three transfer modes: SPP, EPP and ECP. SPP mode (standard parallel
port) is the mode traditionally used to drive a printer. EPP (Enhanced Parallel Port) and ECP
(Extended Capabilities Port) modes are transfer modes that allow transfer rates of 2 and 2.4
Mbytes/s. These modes will only work in connection with peripheral devices which specifically
support them. Cases where these transfer modes are used are, for example, interface conversions
between Parallel and SCSI or Parallel and IDE. The pinouts are different in all three modes.
Pinout in SPP mode (Standard Parallel Port)
Pos.
Signal name
Meaning
1
2-9
10
11
12
13
14
15
16
17
18-25
STROBE
Data Lines 0-7
ACKNOWLEDGE
BUSY
PE
SELECT
AUTO
ERROR
INIT
SELECT IN
GROUND
Data strobe
Data lines 0-7
Data acknowledgement
Not available
End of paper
Select device
Automatic new line
Device error
Reset/Initialize
Select printer
Ground
Pinout in EPP mode (Enhanced Parallel Port)
Pos.
Signal name
Meaning
1
2-9
10
11
12
13
14
15
16
17
18-25
Write
Data Lines
Intr
Wait
reserved
reserved
DStrb
reserved
reserved
AStrb
Ground
Output
Input/output
Input
Input
-
-
Output
-
-
Output
-