Important notes
Power cord selection
6
A26391-K82-Z101-3-7619
Power cord selection
The power cord for this unit has been packed
separately and has been selected for use in the
appropriate country. It must be used to prevent
electric shock. Use the following guidelines if it
is necessary to replace the original cord set.
The female receptacle of the cord set must meet
CEE-22 requirements (see Figure).
For the United States and Canada
Use a UL listed and CSA labeled cord set consisting of a three-conductor cord with a maximum
length of 15 feet.
For units that stand on a desk or table, type SVT or SJT cord sets shall be used.
For units that stand on floor, only SJT type cord sets shall be used.
The cord set must be selected according to the current rating for your unit. Please consult Table A
for the selection criteria for power cords used in the United States and Canada.
Table A:
Cord Type
Size of Conductors
in Cord
Maximum Current
Rating of Unit
SJT
18 AWG
16 AWG
14 AWG
10 Amps
12 Amps
12 Amps
SVT
18 AWG
17 AWG
10 Amps
12 Amps