Fujitsu KVM0108A Скачать руководство пользователя страница 1

CA92344-1926 

User

's

  Guide 

English

Analog KVM Switch

 

User

's

 Guide

November

 

2017

Содержание KVM0108A

Страница 1: ...CA92344 1926 User s Guide English Analog KVM Switch User s Guide November 2017 ...

Страница 2: ......

Страница 3: ...ning pollutants are marked with a symbol a crossed out garbage can They are also marked with the chemical symbol for the heavy metal that causes them to be categorized as containing pollutants Cd Cadmium Hg Mercury Pb Lead Labels on plastic casing parts Please avoid sticking your own labels on plastic parts wherever possible since this makes it difficult to recycle them Returns recycling and dispo...

Страница 4: ...lear power plants automatic airplane flight control air traffic control traffic control in mass transport systems medical devices for life support and missile guidance control in weapons systems hereafter high safety use Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use Please consult the sales staff of Fuji...

Страница 5: ...view 7 Rack Mounting 7 Rack mounting 7 Rack Mounting Rear 8 Optional KVM switch to Rack Console Mounting Rear 8 Single Level KVM Switch Installation 9 Single level installation diagram 9 Tiering multiple KVM switches 9 To set up a Chained tiering installation 10 Chained Tiering Installation Diagram 10 iii Hardware Setup 11 Cable Length Considerations 11 Hot Plugging 11 Powering Off and Restarting ...

Страница 6: ...tion 23 Hotkey Port Control 23 Invoking Hotkey Mode 23 NUM LOCK 23 CTRL F12 23 Hotkey mode environment 23 Exiting hotkey mode 23 Selecting the Active Port 24 Auto Scan Mode Switching 24 Setting the scan interval 24 Invoking Auto Scan 24 Exiting Auto Scan 24 Skip Mode Switching 25 Entering skip mode 25 Exiting skip mode 25 Setting the Hotkey Beeper ON OFF 25 iv Replacement procedure for analog KVM ...

Страница 7: ...ort Operating System 26 Restore the Default Values 26 Hotkey Summary Table 27 Keyboard Emulation 28 Mac Keyboard 28 Sun Keyboard 29 Troubleshooting 30 Overview 30 OSD Factory Default Settings 30 Connection Tables 31 KVM0108A 31 KVM0116A 31 Specifications 32 v Radio Frequency Interference 33 ...

Страница 8: ...b 汞Mercury Hg 鎘 Cadmium Cd 六價鉻 Hexavalent chromium Cr 6 多溴聯苯 Polybrominate d biphenyls PBB 多溴二苯醚 Polybrominate d diphenyl ethers PBDE 電纜線 Cable 印刷電路部件 PCBA 電源模組 Switching Power module 塑膠 其他部件 Plastic Others parts 金屬部件 Metal parts 備考1 超出0 1 wt 及 超出0 01 wt 係指限用物質之百分比含量超出百分比含量基準值 備考2 係指該項限用物質之百分比含量未超出百分比含量基準值 備考3 係指該項限用物質為排除項目 ...

Страница 9: ...ss platform support RJ 45 connectors and cat 5e 6 cabling The KVM0108A or KVM0116A can be installed in a 1U system rack Take advantage of internal network wiring in most modern commercial buildings KVM adapter cables connect to servers Mix PS 2 and USB interfaces connecting the KVM switch to the devices Strong password protection prevents unauthorized access Multiple user accounts Supports up to 1...

Страница 10: ...des If an extension cord is used with this device make sure that the total of the ampere ratings of all products used on this cord does not exceed the extension cord ampere rating Make sure that the total of all products plugged into the wall outlet does not exceed 15 amperes To help protect your system from sudden transient increases and decreases in electrical power use a surge suppressor line c...

Страница 11: ...e slide rails can pinch your fingers After a device is inserted into the rack carefully extend the rail into a locking position and then slide the device into the rack Do not overload the AC supply branch circuit that provides power to the rack The total rack load should not exceed 80 percent of the branch circuit rating Make sure that all equipment used on the rack including power strips and othe...

Страница 12: ...and USB host controller KVM Server Modules KVM Adapter Cable and LAN cables The Cat 5e 6 cable is required to connect the KVM switch to one of the KVM adapter cables The following KVM adapter cables are required for use with the KVM switch Maximum server connections Module Function PY CBKAU11 USB KVM Adapter Cable PY CBKCC1 KVM Cable cascade connection 1 8 m Parent KVM Model Ports Child Tiered KVM...

Страница 13: ...t such as the end of a paper clip or a ballpoint pen To perform a system reset press and release when the unit is running Note This does not clear User Account information 5 Station ID LED The KVM switch s Station ID is displayed here If this is a single station installation or the first station on the installation the KVM switch ID is 01 On a tiered installation the KVM switch auto senses its pos...

Страница 14: ...rt the port on the right is the Chain Out port 3 KVM Port Section The Cat 5e 6 cables that link to the KVM adapter cables which link to the computers plug in here 4 Console Ports If this is a single station installation or if this is the first station of a tiered installation the keyboard monitor and mouse that make up the Local Console plug in here Any combination of USB keyboards and mice for th...

Страница 15: ...ters that have the Keyboard Power On function Rack Mounting Note Allow at least 2 inches 5 1 cm on each side for adequate ventilation and 5 inches 12 7 cm at the rear for power cord and cable clearance The switch can be mounted in a 19 1U rack The mounting brackets can screw into the front or the back of the unit so that it can be attached to the front or back of the rack Rack mounting 1 Position ...

Страница 16: ...her side of the rear of the KVM switch 3 Slide the KVM switch into the rack Align the mounting bracket holes with the holes in the rack 4 Secure the mounting brackets to the rear of the rack Optional KVM switch to Rack Console Mounting Rear The KVM switch can be mounted to a Rack Console not included See the installation sheet for the Rack Console KVM switch bracket kit for more information aem044...

Страница 17: ...VM Adapter Cable and cables on page 4 3 Plug the connectors on the KVM Adapter Cable into the appropriate server ports 4 Plug the supplied power cords into the switch s power sockets then into an AC power source 5 Turn on the servers Single level installation diagram Tiering multiple KVM switches To control even more computers up to 31 additional KVM switches can be tiered from the original KVM sw...

Страница 18: ...ion on page 9 3 Repeat the above steps for any other KVM switches you want to add to the chain 4 Power up the installation as follows a Plug in the power cord for the first level KVM switch Wait for the KVM switch to ascertain its Station ID and display it on the Station ID LED the Station ID for the first level is 01 the ID for the second level is 02 the ID for the third level is 03 etc b Power o...

Страница 19: ...t name operating system and keyboard language will be restored to the KVM switch from any previously used adapter cables after they are plugged in See F3 SET on page 17 and see F4 ADM on page 19 for port setting selections Note 1 If a server operating system doesn t support hot plugging this function may not work properly 2 Empty ports that previously were connected to an KVM Adapter Cable will re...

Страница 20: ...o display its station ID on the front panel LED before powering on the next one 3 After power is on to all KVM switches plug in the Cat 5e 6 cables or power the computers on Port ID Numbering Each server on the installation is assigned a unique port ID The port ID is a one or two segment number that is determined by the level and port number of the switch that is connected to the server The first ...

Страница 21: ... the rack refer to Rack mounting Rear page 8 For the mounting bracket use the bracket removed in Procedure 4 6 Connect the cable removed in Procedure 1 to the KVM switch 7 Connect the power cord to the KVM switch and boot up the KVM switch For the power cord is connected the power turns on automatically and boot up the KVM switch 8 Confirm that the connected server can be referred to from the OSD ...

Страница 22: ...2 The number lock and caps lock will always be on when the OSD is running The OSD uses a two level administrator user password system A valid username and password is required before the OSD Main Screen opens The default username admin and password admin is used the first time that the OSD is accessed For security purposes change these to something unique after you log in the first time The OSD Ma...

Страница 23: ...see the ports for a particular station press the plus sign in front of the station number The port number list opens To close the list press the circle minus sign in front of the station number To move up or down through the list one line at a time press the up and down triangle symbols or use the up and down arrow keys If there are more list entries than room on the Main Screen the list will scro...

Страница 24: ...en press ENTER Note You can enter a partial name or port ID The screen will show all the computers to which the user has View rights that match the name or port ID pattern regardless of the current List settings To return to the OSD Main Menu without making a choice press ESC Heading Explanation SN PN This column lists the port ID numbers station number port number for all the KVM ports on the ins...

Страница 25: ...e administrator and each user can set up an individual working environment A separate profile for each operator is stored by the OSD and is activated according to the username provided during login List Meaning All Lists all of the ports on the installation Quick View Lists only the ports that have been selected as Quick View Ports Powered On Lists only the ports that have attached computers Power...

Страница 26: ...lects which server will be accessed under Skip mode and Auto Scan mode Choices are ALL All the ports which have been set Accessible QUICK VIEW Only those ports which have been set Accessible and selected as Quick View Ports POWERED ON Only ports which have been set Accessible and are Powered On QUICK VIEW POWERED ON Only those ports which have been set Accessible selected as Quick View Ports are P...

Страница 27: ...t an arrowhead displays in the QV column of the List on the Main Screen to indicate selection When a port is deselected the arrowhead disappears If one of the Quick View options is chosen for the List view only a port that has been selected here will display on the List If one of the Quick View options is chosen for Auto Scanning only a port that has been selected here will be Auto Scanned The def...

Страница 28: ...hat the OSD station information corresponds to the new physical layout Set Operating System OS of the server attached to each port You must configure each port on the installation For each port press the SPACEBAR to cycle through the choices WIN Mac or Sun Repeat until all the ports have been set then press ESC The default is WIN WIN Windows OS Note A Sun or Mac computer may not boot when you run ...

Страница 29: ...efore its port ID display To exit Skip mode press the SPACEBAR or ESC F6 BRC F6 is an administrator only function When this function is in effect commands sent from the console are broadcast to all available server on the installation This function is particularly useful for operations that need to be performed on multiple servers such as performing a system wide shutdown installing or upgrading s...

Страница 30: ...is in effect the console will not function normally Exit Auto Scan mode in order to regain control of the console To exit Auto Scan mode press the SPACEBAR or ESC F8 LOGOUT Click in the F8 field or press F8 to log out of the OSD and blank the console screen This is different from deactivating the OSD when from the Main Screen by pressing ESC With this function you must log in all over again to reg...

Страница 31: ...ommand Mode on page 18 To invoke Hotkey mode two possible keystroke sequences shown below can be used see Hotkey on page 18 Only one of the key sequences below can be operational NUM LOCK 1 Hold down the NUM LOCK key 2 Press and release the MINUS key 3 Release the NUM LOCK key CTRL F12 1 Hold down the CTRL key 2 Press and release the F12 key 3 Release the CTRL key Hotkey mode environment When Hotk...

Страница 32: ...lly switches at regular intervals through all the active computer ports accessible to the currently logged on user This allows activity to be monitored automatically See F7 SCAN on page 22 for more information Setting the scan interval The amount of time Auto Scan stays focused on each port is set with the Scan Duration setting of the OSD F3 SET function see F3 SET on page 17 The scan interval can...

Страница 33: ... last accessible port of the each hierarchy station Down arrow to skip to the first accessible port of the each hierarchy station 3 Once in Skip mode continue skipping by pressing the arrow keys The NUM LOCK combination does not have to be used again 4 While Skip mode is engaged ordinary keyboard and mouse functions are suspended Only Skip mode compliant keystrokes can be input Exit Skip mode to r...

Страница 34: ...n the message closes and Hotkey mode is automatically exited Setting the Port Operating System Match a port s operating system configuration to that of the computer attached to the port 1 Invoke Hotkey mode NUM LOCK or CTRL F12 2 Press one of the following function keys After pressing a function key Hotkey mode is automatically exited Restore the Default Values Restore the KVM switch default value...

Страница 35: ... Toggles the Hotkey invocation keys Port ID ENTER Switches access to the computer that corresponds to the Port ID R ENTER Administrator only Hotkey It returns the switch s settings to their default values T Toggles the OSD Hotkey between CTRL CTRL and SCROLL LOCK SCROLL LOCK Invokes Skip Mode and skips from the current port to the first accessible port previous to it Invokes Skip Mode and skips fr...

Страница 36: ...ation mappings are listed in the table below Note When using key combinations press and release the first key CTRL then press and release the activation key PC Keyboard Mac Keyboard SHIFT SHIFT CTRL CTRL CTRL 1 CTRL 2 CTRL 3 CTRL 4 ALT ALT PRINT SCREEN F13 SCROLL LOCK F14 ENTER RETURN BACKSPACE DELETE INSERT HELP CTRL F15 28 ...

Страница 37: ...e corresponding functions are shown below Note When using key combinations press and release the first key CTRL then press and release the activation key PC Keyboard Sun Keyboard CTRL T Stop CTRL F2 Again CTRL F3 Props CTRL F4 Undo CTRL F5 Front CTRL F6 Copy CTRL F7 Open CTRL F8 Paste CTRL F9 Find CTRL F10 Cut CTRL 1 CTRL 2 CTRL 3 CTRL 4 CTRL H Help Compose Meta 29 ...

Страница 38: ...seconds for the system to re initialize the station sequence and display the proper IDs Perform a reset on station ID see Reset Station IDs on page 20 Unplug the chaining cable then plug it back in Setting Default OSD Hotkey SCROLL LOCK SCROLL LOCK Port ID Display Position Upper Left Corner Port ID Display Duration 3 Seconds Port ID Display Mode The Port Number plus the Port Name Scan Duration 5 S...

Страница 39: ...3 160 28 217 224 5 33 40 13 97 104 21 161 168 29 225 232 6 41 48 14 105 112 22 169 176 30 233 240 7 49 56 15 113 120 23 177 184 31 241 248 8 57 64 16 121 128 24 185 192 32 249 256 No Server No Server No Server No Server 1 1 16 9 129 144 17 257 272 25 385 400 2 17 32 10 145 160 18 273 288 26 401 416 3 33 48 11 161 176 19 289 304 27 417 432 4 49 64 12 177 192 20 305 320 28 433 448 5 65 80 13 193 208...

Страница 40: ...e Serial Female Switches Reset 1 x Recessed Pushbutton 1 x Recessed Pushbutton LEDs Port 16 Green Red Orange 16 Green Red Orange Power 1 Blue 1 Blue Station ID 1 Orange 1 Orange Video 1600x1200 60Hz 1600x1200 60Hz I P Rating 100 240VAC 50 60Hz 1 0A 100 240VAC 50 60Hz 1 0A Power Consumption 20 6 W Max 20 6 W Max Environment Operating Temp 32 F 122 F 0 50 C 32 F 122 F 0 50 C Storage Temp 4 F 140 F 2...

Страница 41: ...a residential area is likely to cause harmful interference The user will bear sole responsibility for correcting such interference Canada ICES This Class A digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe A est conforme à la norme NMB 003 du Canada Japan VCCI This is a Class A product based on the standard of the Voluntary Control Council for Interference by In...

Страница 42: ...tes relating to electromagnetic compatibility This product has been tested and found to comply with the limits for Class A Information Technology Equipment according to CISPR 32 European Standard EN 55032 The limits for Class A equipment were derived for commercial and industrial environments to provide a reasonable protection against interference with licensed communication equipment Warning This...

Отзывы: