2-31. E: A1. Discharge temperature error (Outdoor unit)
Indicator
Indoor unit
Operation indicator
10 time flash
Timer indicator
1 time flash
Economy indicator
Continuous flash
Error code
E: A1
Detective actuator
Outdoor unit main PCB
1. →hen the discharge temperature becomes higher
than 110 °C, the compressor stops.
2. After the compressor restarts, if the same operation
is repeated, the compressor stops permanently.
Discharge temperature thermistor
Forecast of cause
Valve is close
EEV failure
Gas leak, less
Discharge thermistor failure
Outdoor fan operation failure
Outdoor heat exchanger clogged
Check point 1. Check if valve is open
If the valve is closed, open the valve and check the operation.
NOTE:
For cooling operation, check gas valve.
For heating operation, check liquid valve.
Check point 2. Check any of the Electronic Expansion Valve (EEV), capillary tube, or strainer, or all
•
Check if EEV open or there is a capillary tube defect.
Refer to outdoor unit Electronic Expansion Valve (EEV) or Capillary tube in
•
Check the strainer clogging.
If EEV, Capillary tube or Strainer is defective, replace it.
Check point 3. Check if gas leak or less gas
Measure gas pressure, if there is a leak, correct it.
If recharging refrigerant, make sure to perform vacuuming and recharge the specified amount.
Check point 4. Check the discharge thermistor
•
Isn’t it fallen off the holder?
•
Is there a cable pinched?
Check characteristics of thermistor (Refer to
"E: 71. Discharge thermistor error (Outdoor unit)"
page 03-26). If defective, replace the thermistor.
Check point 5. Check the outdoor unit fan and heat exchanger
•
Is there anything obstructing the air distribution circuit?
•
Is there any clogging of outdoor heat exchanger?
•
Is the fan rotating? (Check by hand and if it is locked, replace the motor.)
•
Check outdoor fan motor.
If the fan motor is defective, replace it.
2-31. E: A1. Discharge temperature error (Outdoor unit)
- (03-37) -
2. Troubleshooting with error code
TR
O
U
B
LESH
O
O
TI
N
G
TR
O
U
B
LESH
O
O
TI
N
G
Содержание GENERAL AOHG18KMTA
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2022 03 11 SR_CH01_AS070EG_01 ...
Страница 15: ...2 TECHNICAL DATA AND PARTS LIST 2022 03 11 SR_CH02_AS070EG_02 ...
Страница 40: ...7 3 Model AOHG24KMTA 02 24 7 PC board diagrams TECHNICAL DATA AND PARTS LIST TECHNICAL DATA AND PARTS LIST ...
Страница 41: ...3 TROUBLESHOOTING 2022 03 25 SR_CH03_AS070EG_01 ...
Страница 44: ......
Страница 103: ...4 CONTROL AND FUNCTIONS 2022 03 25 SR_CH04_AS070EG_01 ...
Страница 105: ...8 8 High temperature and high pressure release control heating mode 04 29 CONTENTS continued ...
Страница 106: ......
Страница 137: ...5 FILED WORKING 2022 03 25 SR_CH05_AS070EG_01 ...