3.73: TMGOUTPSW
Issue 9, May 1999
FNC and FNC Customer Use Only
Vol. ll, Page 480.3-46
Maintenance and Trouble Clearing
FJTU-320-515-480
3.73
TMGOUTPSW
TMGOUTPSWPRS/STU/ST2/ST3/SIC/ST4/RES/FAIL/NA
3.74
TMGOUTSSW
TMGOUTSSWPRS/STU/ST2/ST3/SIC/ST4/RES/FAIL/NA
Table 3-71: TMGOUPSW (Primary DS1 Timing Reference Output Switch)—Transient Condition
AID
Type
Direction
Probable Cause
Suggested Corrective Action
SYNCIN
NA
A derived DS1 primary
timing reference switch is
detected.
• The TCA-ENH unit is defective.
• Check the upstream ADM for optical channel
unit failure or removal.
• Check the fiber-optic path and perform trouble
analysis as needed.
Table 3-72: TMGOUTSSW (Secondary DS1 Timing Reference Output Switch)—Transient Condition
AID
Type
Direction
Probable Cause
Suggested Corrective Action
SYNCIN
NA
A derived DS1 secondary
timing reference switch is
detected.
• The TCA-ENH unit is defective.
• Check the upstream ADM for optical channel
unit failure or removal.
• Check the fiber optic-path and perform trouble
analysis as needed.