3.63: SYNCD
Issue 9, May 1999
FNC and FNC Customer Use Only
Vol. ll, Page 480.3-38
Maintenance and Trouble Clearing
FJTU-320-515-480
3.63
SYNCD
3.64
SYSRES
3.65
T-FE
Table 3-61: SYNCD (Synchronization Message Degradation)—Alarm Event
AID
Type
Direction
Probable Cause
Suggested Corrective Action
SYNCIN
NA
Synchronization
message degradation is
detected.
• Replace the TCA-ENH unit.
• Check the upstream ADM for optical channel
unit failure or removal.
• Check the fiber-optic path and perform trouble
analysis as needed.
Table 3-62: SYSRES (System Restart)—Transient Condition
AID
Type
Direction
Probable Cause
Suggested Corrective Action
COM
NA
The system was restarted.
Monitor system to determine reason for restart
not initiated by technician.
Table 3-63: T-FE (Threshold Violation)—Transient Condition
AID
Type
Direction
Probable Cause
Suggested Corrective Action
OVTG
NA
A threshold violation
occurred on the far-end NE.
Retrieve PM from far-end NE to determine cause
of errors.