3.49: MAN
Issue 9, May 1999
FNC and FNC Customer Use Only
Vol. ll, Page 480.3-30
Maintenance and Trouble Clearing
FJTU-320-515-480
3.49
MAN
3.50
MANSW
The Working/Protect entity has been switched to the Protect/Working entity,
based on the fault-free operating status of the switched-to entity.
Table 3-47: MAN (Manually Caused Abnormal Condition)—Alarm Event
AID
Type
Direction
Probable Cause
Suggested Corrective Action
COM
NA
The system is in an operator-
caused abnormal condition
(forced or lockin protection
switching, or loopback).
Corrective action is not necessarily required. The
manual condition will automatically clear when
the operator removes the forced switch, loopback,
or lockin condition.
Table 3-48: MANSW (Manual Switch of Working/Protect to Protect/Working)—
Standing Condition
AID
Type
Direction
Probable Cause
Suggested Corrective Action
COM
NA
OPR-PROTNSW-COM:
TID:AIDs:CTAG::MAN;
has been executed for
testing or maintenance
reasons.
•
Verify that the cause of operating the forced
switch no longer exists or that authorization to
release the manual switch is secured.
•
Execute the RLS-PROTNSW-COM command.
EQPT
NA
OPR-PROTNSW-EQPT:
TID:AIDs:CTAG::MAN;
has been executed for
testing or maintenance
reasons.
•
Verify that the cause of operating the forced
switch no longer exists or that authorization to
release the manual switch is secured.
•
Execute the RLS-PROTNSW-EQPT command.
OC-3
NA
OPR-PROTNSW-OC3:
TID:AIDs:CTAG::MAN;
has been executed for
testing or maintenance
reasons.
•
Verify that the cause of operating the forced
switch no longer exists or that authorization to
release the manual switch is secured.
•
Execute the RLS-PROTNSW-OC3 command.
OVTG
NA
OPR-PROTNSW-OVTG:
TID:AIDs:CTAG::MAN;
has been executed for
testing or maintenance
reasons.
•
Verify that the cause of operating the forced
switch no longer exists or that authorization to
release the manual switch is secured.
•
Execute the RLS-PROTNSW-OVTG command.