Point
The communication method between this product and fibre channel switch (Fabric OS v6.3 or later) has been changed from
telnet to SSH. If the SSH feature is disabled on the targeted switch, enable the SSH feature. Refer to the manual provided by the
equipment for details on setting the SSH feature.
Note
When executing the
command, if a managed device or server is not accessible, the
command should be re-executed since the device configuration information is not imported.
7.
Uninstalling Symfoware
In the version level of this ETERNUS SF Manager, Symfoware is not used.
Symfoware should only be installed in cases where it was used by ETERNUS SF Manager only.
The procedures to uninstall Symfoware are stated below.
-
Uninstall Symfoware from the Add or Remove Programs or Programs and Features page.
If both Symfoware Server and Symfoware Client are installed, uninstall Symfoware Client first.
Point
-
If the ETERNUS VASA Provider was being used with the previous version
It is necessary to reinstall a version of the ETERNUS VASA Provider that supports this version.
-
If the Fujitsu ETERNUS Storage Systems Monitoring Pack was being used with the previous version
It is necessary to reinstall a version of the Fujitsu ETERNUS Storage Systems Monitoring Pack that supports this version.
6.1.2.6 Tasks to Be Performed After Upgrade (Secondary Node)
The tasks below need to be performed on the secondary node.
1.
Check that the ETERNUS SF Manager services are stopped.
If not stopped, use the Failover Cluster Manager to stop the transactions of ETERNUS SF Manager.
2.
Restore the operation environment of the previous version of the Storage Cruiser's manager.
Note that if step a and step b have already been performed, perform from step c.
a.
Log on to the server using Administrator privileges.
b.
Insert the DVD-ROM "ETERNUS SF SC/ACM/Express Mediapack for Windows (Manager Program) (1/2)" for this version into
the DVD-ROM drive.
Refer to "DVD-ROM Contents" in the
ETERNUS SF Installation and Setup Guide
for this version for information on the DVD-
ROM structure and detailed contents.
c.
Mount the shared disk for shared data of ETERNUS SF Manager.
If it is mounted on the primary node, unmount it to mount on the secondary node.
d.
Implement restoration of the previous version.
Execute the following batch file. For
backupDir
, specify the directory in which the backup data is stored with an absolute
path. For
tmpDir
, specify a directory in which to temporarily place the files related to the performance management
function with an absolute path. When the performance management function is not backed up, it is unnecessary to specify
a directory for the
tmpDir
.
dvdromDrive:\Manager_windows\vuptools\esfpostinst_cluster.bat backupDir [tmpDir] -secondary
When the restore fails, after confirming the output error message and removing the cause of the failure, execute the batch
again.
- 54 -