Chapter 6 Changing the Multipath Configuration (iSCSI Connection for RHEL5, SLES9, or SLES10)
6.3 LU Addition
FUJITSU Storage ETERNUS Multipath Driver V2 User’s Guide for Linux
Copyright 2014 FUJITSU LIMITED
P2U3-0031-15ENZ0
76
4
Restart the server.
Power on the server and boot it up.
5
Use the "iompadm info" command to check that the removed hardware is displayed as "fail".
[Example]
6
Delete the removed hardware from the Multipath Driver target list using the "mpdconfig -d"
command.
[Example]
7
If the recognition order function is being used, execute the "mpdconfig -s" command to
reconfigure the recognition order.
[Example]
8
Use the "iompadm info" command to check the result.
[Example]
9
Set the iSCSI service and delete the iSCSI target information of the removed storage system.
End of procedure
6.3
LU Addition
Same as for FC/FCoE connection.
Refer to
"4.1 Storage System and LU Addition" (page 54)
6.4
LU Reduction
Same as for FC/FCoE connection.
Refer to
"4.2 Storage System and LU Reduction" (page 57)
.
# /opt/FJSVmpd/bin/iompadm info
# /opt/FJSVmpd/bin/mpdconfig -d
# /opt/FJSVmpd/bin/mpdconfig -s
# /opt/FJSVmpd/bin/iompadm info