Chapter 5 Servicing the Tape Library
5.9 Removing and Replacing the Base Chassis
FUJITSU Storage ETERNUS LT40 S2/LT60 S2 LTO Library Installing, Starting Up and Maintaining
Copyright 2018 FUJITSU LIMITED
P3AM-5392-07ENZ0
94
Figure 5.10 ETERNUS LT40 S2: Operations, Magazine page
End of procedure
5.9
Removing and Replacing the Base Chassis
You will need a #3 Phillips screwdriver to remove and replace the base chassis assembly. Before beginning, be
sure the tape drive or drives do not contain a tape cartridge. To remove a cartridge, see section
Moving Media Within the Library" (page 66)
.
■
To remove the components in the base chassis and the base chassis from the rack
Procedure
1
Obtain adequate assistance to lift and stabilize the library during removal and replacement.
2
Remove the magazines from the library.
3
Turn off power to the library and disconnect all cables.
4
Remove the library from the rack:
•
From the front of the library loosen the two screws anchoring the mounting brackets on the library
to the rack. These are captive screws and cannot be removed.
•
Remove your library from the rack.
5
Remove the replacement library enclosure from the packing materials.
6
Place the replacement library enclosure on a solid surface in preparation for installation in
to the rack.
Содержание ETERNUS LT40 S2
Страница 2: ...This page is intentionally left blank ...
Страница 110: ......