ETERNUS LT20 S2
17
3
Installing the Tape Library
3.1
Location Requirements
Choose a location that meets the following criteria:
Criteria
Definition
Rack requirements
Standard 19-inch rack with 1U of clearance
Room temperature
10-35º C (50-95º F)
Power source
AC power voltage: 100-127 VAC; 200-240 VAC
Line frequency: 50-60 Hz
Place the library near an AC outlet. The AC power
cord is the product's main AC disconnect device and
must be easily accessible at all times.
Weight without media
14 kg
Weight with media
(8 LTO cartridges)
16.5 kg
Air quality
The library should be placed in an area with minimal
sources of particulate contamination.
Avoid areas near frequently used doors and
walkways, stacks of supplies that collect dust, printers,
and smoke-filled rooms.
Excessive dust and debris can damage tapes and
tape drive.
Humidity
20-80 percent RH non-condensing
Clearance
Back: Minimum of 15.4 cm (6 inches)
Front: Minimum of 30.8 cm (12 inches) – for mailslot
Minimum of 60 cm to remove magazines (24 inches)
Sides: Minimum of 5.08 cm (2 inches)