6.1.2.2
iSCSI Port Parameter Settings
Set the connection information between the host interface port and the server.
The procedure to set the port parameters is as follows.
The setting screen that is displayed depends on the host interface port that is being used.
Set the connection information for the iSCSI ports on the ETERNUS DX and the server.
1
On the navigation of the ETERNUS Web GUI screen, click the [Connectivity] tab.
2
Select which iSCSI port to set the port parameters for and click [Configure iSCSI Port] in [Action].
The [Modify iSCSI Port Parameters] screen appears.
3
Select the target port, specify the items (for TCP/IP settings, iSCSI settings, basic settings, and security
settings), and then click the [Set] button.
•
iSCSI Name can be managed more easily if the port name is added to the end of the default.
•
When multiple target ports are selected, the parameters must be set for multiple ports.
Select the port to be set from the pull-down menu.
The following items are set as shown in this example.
•
Port
CM#0 CA#0 Port#0
•
IP Version
Select an IP address type. IPv4 is used in this example.
•
IP Address
Specify an available IP address for the iSCSI network that is to be connected.
For IPv4, the subnet mask needs to be specified.
•
iSCSI Name
For multipath connections, each name must be different.
•
CHAP
Specify [ON] to use unidirectional CHAP authentication or bidirectional CHAP authentication for the
target port and [OFF] to use neither of them.
Chapter 6 SAN Connection Settings
6.1 Connection Settings for the ETERNUS DX
89
FUJITSU Storage ETERNUS DX500 S3/DX600 S3 Disk storage system Configuration Guide (Basic)
Copyright 2014 FUJITSU LIMITED
P3AM-7732-05ENZ0
Содержание Eternus DX500 S3
Страница 2: ...This page is intentionally left blank ...
Страница 151: ......