Chapter 4 Connectivity Management
4.3 CA Port Group Management
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED
P2X0-1270-13ENZ0
446
5
Specify the parameter that is not to be copied and click the [Set] button.
A confirmation screen appears.
6
Click the [OK] button.
Setting of the FC port parameters starts.
7
Click the [Done] button to return to the [FC Port] screen.
End of procedure
4.3.8
Modify iSCSI Port Parameters
This function sets the parameters for the iSCSI host interface port that connects between the ETERNUS DX and
the host, or connects between the storage systems for REC.
•
The "parameter that is not to be copied" indicates the "Loop ID" setting for "Set Loop ID (Manual)".
When the connection type is "FC-AL" and the Loop ID setting is "Manual", specify the "Loop ID"
value after copying of the parameters is complete.
•
If the Loop ID is changed while a server is operating, reboot the server immediately. If the server is
operated without being rebooted, a warning message may appear or a system failure may occur.
•
If the parameters do not satisfy the input conditions, an error screen appears. Check the parameter
settings.
•
When changing port parameters during operation, stop access from the server that is allocated to the
target port. Host access does not need to be stopped to change the port parameters of newly added CA
ports.
•
Multiple VLAN can be set for ports with "CA" or "CA/RA" as the port mode. For "CA/RA" ports, IP addresses
that are added (15 addresses in maximum) can be used as "CA" type ports.
•
When the Multiple VLAN setting is enabled and the port mode for the relevant iSCSI ports is changed from
"CA" or "CA/RA" to "RA", all of the added IP address information is deleted. Refer to
for details.
•
There are three port modes for an iSCSI port; CA, RA, and CA/RA. CA is used for connecting to a server, RA
is used for REC, and CA/RA is used for connecting to a server and for REC. To switch the port mode, refer to
"4.3.11 Modify Port Mode" (page 459)
. The default value is "CA".
•
iSCSI RA (for older storage system connection) is an iSCSI-RA adapter that is used exclusively for an REC
between the ETERNUS DX500 S3/DX600 S3 and older storage systems (*1).
*1:
ETERNUS DX400 series, ETERNUS DX8000 series, ETERNUS4000, or ETERNUS8000
•
For more details on iSCSI-CA parameter settings, refer to "FUJITSU Storage ETERNUS DX Configuration
Guide -Server Connection-" for each OS type.
Содержание Eternus DX200F
Страница 2: ...This page is intentionally left blank ...
Страница 1082: ......