■
Host Interfaces
A host interface (CA) is an adapter that has interface ports to connect a controller to a server.
The following table shows the maximum number of host interfaces that can be installed per controller.
Table 86
Maximum Number of Host Interfaces per Controller
Model
Maximum number of host interfaces
ETERNUS DX60 S5
1
ETERNUS DX100 S5
2
ETERNUS DX200 S5
2
ETERNUS DX500 S5
2
ETERNUS DX600 S5
4
ETERNUS DX900 S5
4
Host interfaces can be added during system operation. When an error occurs, a replacement can be made while
the system is running.
FC, iSCSI, and SAS are available as the SAN host interface. Ethernet is available as the NAS host interface.
Different types of interfaces can exist together in the same controller.
The host interface specifications are shown below.
Table 87
Host Interface Specifications
Interface
Transfer rate (max.)
Connector type
Number of ports for each CA
FC
32Gbit/s
LC
2 / 4 (*1)
FC
16Gbit/s
LC
2 / 4
FC
8Gbit/s
LC
2 (*2)
iSCSI (*3)
10Gbit/s
LC
2
iSCSI
10Gbit/s
SFP+ (direct attach twinax
copper)
2
iSCSI (*4)
10Gbit/s
RJ-45
2
iSCSI
1Gbit/s
RJ-45
2
SAS
12Gbit/s
miniSAS HD (SFF-8644)
2
Ethernet (*3)
10Gbit/s
LC
2
Ethernet
10Gbit/s
SFP+ (direct attach twinax
copper)
2
Ethernet
1Gbit/s
RJ-45
4
*1:
FC 32Gbit/s host interfaces can be installed in the ETERNUS DX100 S5/DX200 S5 and the ETERNUS DX500 S5/DX600 S5/DX900 S5.
*2:
FC 8Gbit/s host interfaces can be installed in the ETERNUS DX60 S5 only.
*3:
The SFP+ module is required.
*4:
iSCSI (10GBASE-T) can be installed in the ETERNUS DX60 S5 and the ETERNUS DX100 S5/DX200 S5 only.
6. Hardware Configurations
Controller Enclosure
259
Design Guide
Содержание ETERNUS DX S5 Series
Страница 335: ......