2.5.2
For Driver Versions Before V6.30g
Edit the configuration file according to the following parameter list.
2.5.2.1
lpfc.conf Parameter Values
Parameter
Setting value
(for direct connection)
Setting value
(for switch connec-
tion)
lpfcX
(Instance name)
Remarks
log-verbose
0x0
0x0
—
—
log-only
1
1
—
—
lpfcX-fcp-bind-method
4
2
Yes
An instance name is
specified for each in-
stance.
fcp-bind-WWNN
Not required
Not required
—
—
fcp-bind-WWPN
Not required
(*1)
—
—
fcp-bind-DID
Not required
Not required
—
—
lpfcX-automap
1
0
Yes
An instance name is
specified for each in-
stance.
lun-queue-depth
•
For the ETERNUS
DX60 S2/DX80 S2/
DX90 S2: Not re-
quired
•
For the ETERNUS
DX400 S2 series and
the ETERNUS DX8000
S2 series: 20
•
For the ETERNUS
DX60 S2/DX80 S2/
DX90 S2: Not re-
quired
•
For the ETERNUS
DX400 S2 series and
the ETERNUS DX8000
S2 series: 20
—
—
tgt-queue-depth
•
For the ETERNUS
DX60 S2/DX80 S2/
DX90 S2: Not re-
quired
•
For the ETERNUS
DX400 S2 series and
the ETERNUS DX8000
S2 series: 512
•
For the ETERNUS
DX60 S2/DX80 S2/
DX90 S2: Not re-
quired
•
For the ETERNUS
DX400 S2 series and
the ETERNUS DX8000
S2 series: 512
—
—
lpfcNtM-lun-throttle
Not required
Not required
—
—
lpfcNtM-tgt-throttle
•
For the ETERNUS
DX60 S2/DX80 S2/
DX90 S2: 40
•
For the ETERNUS
DX400 S2 series and
the ETERNUS DX8000
S2 series: Not re-
quired
•
For the ETERNUS
DX60 S2/DX80 S2/
DX90 S2:
40
¸
(No. of Server-
side Fibre Channel
ports connected to
each ETERNUS-side
CA port) (Round the
result down)
Use the value of "8" if
the actual result is
lower.
•
For the ETERNUS
DX400 S2 series and
the ETERNUS DX8000
S2 series: Not re-
quired
—
—
no-device-delay
0
0
—
—
network-on
0
0
—
—
Chapter 2 Setup Procedure for Emulex Fibre Channel Cards
2.5 Required Driver Parameters
47
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Oracle Solaris
Copyright 2017 FUJITSU LIMITED