Deleting a Remote User
Delete a remote user if the OST user credentials are no longer needed to authenticate an LSU
for Automatic Image Replication.
To delete a remote user, select the user and click
Delete
.
You can seleYou can select multiple users to delete at once.ct multiple users to
delete at once.
10.4.6
Target IP Mapping
The
Target IP Mapping
page allows you to map a target data IP address to route all network
traffic sent to the data IP address to the specified replication IP address instead. This can be
necessary if the target ETERNUS CS800 is configured with different network interfaces (and
therefore different IP addresses) for data and replication traffic (see
).
Generally, OST traffic is routed to the data network segment. However, the OST Automatic
Image Replication (AIR) and Concurrent Optimized Duplication features use the replication
network segment to transmit data to the target system. (Optimized duplication can optionally
use the replication channel.) When a data IP address is mapped to a replication IP address,
OST traffic that is sent to one of the IP addresses is routed to the other IP address as
necessary.
You must add target IP mapping information if you are performing optimized
duplication on a segmented network and replication is not configured between the
source ETERNUS CS800 and target ETERNUS CS800.
Fujitsu Technology Solutions does not recommend mapping multiple data IP
addresses to a single replication IP address. If you have mapped multiple data IP
addresses and the routing is not working, try removing the additional data IP
addresses, and map only a single data IP address.
To access the
Target IP Mapping
page, on the
OST
page, click the
Target IP Mapping
tab
(see
"Target IP Mapping Page" on page 266
).
ETERNUS CS800
265
10 Configuration
Содержание ETERNUS CS800
Страница 1: ...ETERNUS CS800 V3 2 User Guide English ...
Страница 2: ......
Страница 3: ...English ETERNUS CS800 User Guide V3 2 Edition October 2015 ...
Страница 26: ...26 ...
Страница 42: ...42 ...
Страница 78: ...78 ...
Страница 114: ...6 3 Running the Getting Started Wizard 6 3 3 Network Configuration Figure 80 Network Configuration 114 ETERNUS CS800 ...
Страница 132: ...6 3 Running the Getting Started Wizard Figure 91 Confirm Page 132 ETERNUS CS800 ...
Страница 143: ...Figure 97 Remote Management Pages Map ETERNUS CS800 143 7 Remote Management ...
Страница 144: ...144 ...
Страница 184: ...8 7 AIS Connect Figure 128 AISConnect Wizard Confirm 184 ETERNUS CS800 ...
Страница 198: ...198 ...
Страница 321: ...Figure 206 Network Configuration ETERNUS CS800 321 10 Configuration ...
Страница 335: ...Figure 215 Date Time Page To set the system date and time ETERNUS CS800 335 10 Configuration ...
Страница 339: ...Figure 216 Access Control Settings Page ETERNUS CS800 339 10 Configuration ...
Страница 362: ...362 ...
Страница 432: ...432 ...
Страница 476: ...476 ...
Страница 494: ...494 ...
Страница 600: ...600 ...