3.4 Turning On and Shutting Down the System
3.4
Turning On and Shutting Down the System
Turning on the System
To turn on the ETERNUS CS800 S6, proceed as follows:
Entry model only:
1. Switch on the ETERNUS CS800 system by pressing the power buttons located on the
front of the system
2. If storage module is installed, it is switched on automatically.
3. Wait 15 minutes for the system to boot before continuing with the procedure.
Scale variant only:
1. a) Switch on both PSU switches on the rear side of each storage base and expansion
module.
b) Check that the LINE LEDs of all storage expansion modules are green.
c) At the storage base module, press the power ON/OFF button which is located at the
front panel on the left side.
d) Wait until the READY LED of the storage base module glows green.
2. At the server module, press the power ON/OFF button which is located at the front
panel on the right side.
3. Wait about 15 minutes before starting any further actions (such as configurations via
software).
Shutting down the system
To shut down the ETERNUS CS800 S6, use the remote management pages (see
). Shutting down the system can take up to 15 minutes. The server
is switched off and goes into standby mode. The Power-off indicator lights up green. If the
operating system does not switch the server off automatically, press the ON/OFF button for
at least 10 seconds and/or send a corresponding control signal.
The storage modules are not switched off by shutting down the ETERNUS CS800 S6 via the
remote management pages. If you want to switch off the storage modules completely,
wait until the server has shut down, then press the Power ON/OFF button of the storage
base module(s) for several seconds until the READY LED does not glow any more. This can
take about 10 seconds. Then wait until DX100 S3 has shut down itself, i.e. its power LED
goes off.
ETERNUS CS800
72
Содержание ETERNUS CS800 S6
Страница 1: ...English ETERNUS CS800 S6 User Guide V3 2 7 Edition April 2017 ...
Страница 131: ...7 3 The Remote Management Console Figure 98 Remote Management Pages Map ETERNUS CS800 131 ...
Страница 173: ...8 8 AIS Connect Figure 132 AISConnect Wizard Confirm ETERNUS CS800 173 ...
Страница 449: ...16 2 Storage Subsystem Figure 313 Inserting the 3 5 inch HDD module ETERNUS CS800 449 ...