3.2 Storage Modules
Figure 33: Power supply unit (PSU) of the ETERNUS JX40 S2
Explanation
l
Inlet: This inlet is used to connect a power cord.
l
PSU switch: This switch is used to turn on and off the AC power supply.
LED name
LED status
Description
POWER LED
green
blinks green
AC power is supplied to the power supply unit.
AC power is supplied to the power supply unit, but
DC power is not supplied to the storage subsystem.
FAULT LED
amber
AC power is not supplied to the power supply unit.
AC MISSING LED
amber
AC power is not supplied to this power supply unit,
but AC power is supplied to the other power supply
unit.
FAN LED
amber
The power supply unit or the fan in the power
supply unit is in error status.
Table 11: Status and meanings of each LED (power supply unit)
For detailed information on ETERNUS JX40 S2 storage module see
3.2.3
ETERNUS DX100 S3 Base Module - Front View
The Scale model of ETERNUS CS800 S6 uses ETERNUS DX100 S3 storage modules as backup
data storage. There are two variants of the ETERNUS DX100 S3 storage modules:
l
a storage base module (controller enclosure) which is connected to the server
component, and up to ten optional
ETERNUS CS800