BX2560 M2
D3320 - BIOS Setup Utility
57
Server Mgmt menu
Pressing the
[+]
key or the
{-}
key increases or decreases this value.
Temperature Monitoring
Specifies whether the system is disabled if the ambient temperature or
the temperature of a processor exceeds the critical value. This protects
against damage to the system or data. If the operating system has an
active server management process, it takes over the temperature
monitoring function and shuts the system down if the temperature values
reach a critical level.
Depending on the
Boot Retry Counter
, the system is enabled again after
the time set under
ASR&R Boot Delay
has expired. The system should
have cooled down again during this period.
Disabled
The system does not switch off itself if the temperature exceeds
the critical value.
Enabled
The system switches off itself if the temperature exceeds the
critical value.
Event Log Full Mode
Specifies whether or not the System Event Log can be overwritten.
Overwrite
If the System Event Log is full, additional events overwrite the
oldest entries in the System Event Log. In this case, newer events
are more important than older events.
Maintain
If the System Event Log is full, no further events are entered. The
System Event Log file must be cleared first before additional
events can be entered. In this case, older events are more
important than newer events.
Load iRMC Default Values
Specifies whether the iRMC default values are loaded or not.
No
No action is taken.
Содержание D3320 PRIMERGY BX2560 M2
Страница 12: ...12 D3320 BIOS Setup Utility BX2560 M2 Navigating the BIOS setup utility ...
Страница 52: ...52 D3320 BIOS Setup Utility BX2560 M2 Security menu ...
Страница 76: ...76 D3320 BIOS Setup Utility BX2560 M2 Flash BIOS Update ...
Страница 80: ...80 D3320 BIOS Setup Utility BX2560 M2 Index X xHCI Mode 38 ...