background image

System Board D2542
for RX100 S5  

Technical Manual

Edition November 2009

Содержание D2542

Страница 1: ...System Board D2542 for RX100 S5 Technical Manual Edition November 2009 ...

Страница 2: ...a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2000 cognitas Gesellschaft für Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright 2007 Fujitsu Siemens Computers GmbH All rights reserved Delivery subject to av...

Страница 3: ...cate 10 2 3 Environmental Protection 11 3 Features 13 3 1 Overview 13 3 2 Main memory 17 3 3 PCI bus 18 3 4 Screen resolution 19 3 5 Temperature system monitoring 19 3 6 LEDs 21 3 7 Interfaces and connectors 23 3 7 1 External ports 24 3 8 Settings with jumpers 26 4 Replacing the lithium battery 27 Abbreviations 29 ...

Страница 4: ......

Страница 5: ...ont indicate system output on the monitor semi bold fixed font indicates values to be entered through the keyboard Key symbol indicates keys according to their representation on the keyboard If capital letters are to be entered explicitly then the Shift key is shown e g SHIFT A for A If two keys need to be pressed at the same time then this is shown by placing a hyphen between the two key symbols ...

Страница 6: ......

Страница 7: ...Any failure to observe the guidelines in this manual and any unauthorized openings and improper repairs could expose the user to risks electric shock fire hazards and could also damage the equipment Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability Transport the device only in the antistatic original packaging ...

Страница 8: ...As minimum requirement the use of a protected LAN line of category 5 for 10 100 MBps Ethernet and or of category 5e for Gigabit Ethernet is considered The requirements of the specification ISO IEC 11801 are to be considered Never connect or disconnect data transmission lines during a storm lightning hazard Batteries V CAUTION Incorrect replacement of lithium battery may lead to a risk of explosion...

Страница 9: ...ouching a grounded object before working The equipment and tools you use must be free of static charges Remove the power plug from the power socket before inserting or removing boards containing ESDs Always hold boards with ESDs by their edges Never touch pins or conductors on boards fitted with ESDs Use a grounding cable designed for this purpose to connect yourself to the system unit as you inst...

Страница 10: ...when you insert or remove boards Take great care to ensure that extension boards are slotted in straight without damaging components or conductors on the system board or any other components for example EMI spring contacts Be careful with the locking mechanisms catches centring pins etc when you replace the system board or components on it for example memory modules or processors Never use sharp o...

Страница 11: ...and should be switched off during long breaks and on completion of work Notes on packaging Please do not throw away the packaging We recommend that you do not throw away the original packaging in case you need it later for transporting Notes on dealing with consumables Please dispose batteries in accordance with local government regulations Do not throw batteries and accumulators into the househol...

Страница 12: ...D 33106 Paderborn Tel 49 5251 8 18010 Fax 49 5251 8 18015 The device may not be disposed of with household rubbish This appliance is labelled in accordance with European Directive 2002 96 EC concerning used electrical and electronic appliances waste electrical and electronic equipment WEEE The guideline determines the framework for the return and recycling of used appliances as applicable througho...

Страница 13: ...ond level cache depending on the processor Main memory Up to 4 slots for main memory DDR II 800 PC2 6400 SDRAM unbuffered Maximum 16 Gbyte of memory Memory modules for 512 MB 1 GB 2 GB and 4 GB Supports dual channel DDR2 interface with interleaved mode Supports ECC Error Correction Code Chips on the system board Intel chipset Bigby P Southbridge Intel ICH9 R SATA Southbridge Intel ICH9 SAS SAS Con...

Страница 14: ...shield 2x USB 2 0 ports 1x VGA port 15 pin 1x keyboard port 1x mouse port 1x RS 232 C interface serial 9 pin 2x RJ45 LAN ports onboard LAN 1x RJ45 service LAN port Internal connectors SATA System Board 3 serial SATA SAS SATA BP LED Front panel NMI Reset SAS System Board 1 serial SATA 1 SAS SAS SATA BP LED Front panel NMI Reset ...

Страница 15: ...pport DMI function support System security Power on Password and Setup Password Boot possible from CD DVD ROM Hard disk LAN USB Environmental protection Battery in holder for recycling Form factor 260 mm x 305 mm CSS Customer Self Service This system board supports the CSS functionality You will find a description of CSS functionality in the operating manual of your server ...

Страница 16: ...formation refer to the Fujitsu Siemens Computers BIOS manual V CAUTION When using the TPM note the program descriptions provided by the third party manufacturers You must also create a backup of the TPM content To do this follow the third party manufacturer s instructions Without this backup if the TPM or the system board is faulty you will not be able to access your data If a failure occurs pleas...

Страница 17: ...modules in the Opttion Guide of your server Module population Figure 2 Assembly of the main memory with memory banks and memory modules Population of the memory Already populated by basic configuration Basic DIMM1A DIMM2A DIMM1B DIMM2B 1 x memory module x Table 2 Basic configuration with 1 memory module Basic DIMM1A DIMM2A DIMM1B DIMM2B 1 x memory module x x 2 x memory modules x x x 3 x memory mod...

Страница 18: ... an overview of the PCI slots Basic DIMM1A DIMM2A DIMM1B DIMM2B 2 x memory modules x x Table 4 Basic configuration with 2 memory modules Basic DIMM1A DIMM2A DIMM1B DIMM2B 2 x memory modules x x x x Table 5 Basic configuration with 2 memory modules and 2 additional memory modules PCI bus Signal level Slot no Length PCI E x8 1 1x low profile or standard slot max length 175 mm PCI E x8 2 1x low profi...

Страница 19: ...ainst damage caused by overheating In addition any unnecessary noise is also prevented by reducing the fan speed and information is provided about the system status The temperature and system monitoring are controlled by an onboard controller The following functions are supported Temperature monitoring Measurement of the processor temperature of the system board temperature measurement of the ambi...

Страница 20: ... detected Should this happen all fans monitored by this sensor run at maximum speed to achieve the greatest possible protection of the hardware Voltage monitoring When voltage exceeds warning level high an alert will be generated System Event Log SEL All monitored events of the system board are recorded in the System Event Log ...

Страница 21: ...ver LED A and LED B are different functionalities of the same LED and are glowing diffe rently All the other LEDs are only visible if the cover of the server has been opened CPU DIMM2B DIMM1B DIMM2A DIMM1A Fan3 Sys iRMC CSS indicate button Optional riser card Fan2 Sys Fan1 Sys Fan4 Sys Fan5 Sys for PCI slot 1 for PCI slot 2 E D B A C G F E G ...

Страница 22: ...r LED red indicates a prefailure red flashing indicates a failure Reasons for a failure may be overheating of one of the sensors sensor defect fan defect CPU error Software detected an error B CSS Customer Self Service yellow indicates a prefailure yellow flashing indicates a failure C Identification blue server is identified via ServerView D memory orange memory module failure E system fans orang...

Страница 23: ...nly for SATA version 11 SATA 1 connector only SATA version 2 power supply for I2 C 12 System fan 3 3 power supply ATX 13 System fan 2 4 system fan 5 14 System fan 1 5 front panel 15 CSS module 6 power supply ATX 12 V CPU 16 slots for memory modules 1 2 3 4 5 6 7 15 8 10 11 13 14 17 9 18 19 12 16 CPU DIMM2B DIMM1B DIMM2A DIMM1A iRMC Battery CSS indicate button LSI 1064E ...

Страница 24: ...em to the iRMC via LAN The LAN connection only LAN port 1 can be exclusive for management or be shared with the standard OS 7 System fan 4 17 CSS indicate button 8 SAS SATA BP LED 18 external ports 9 SAS connector only SAS version 19 slot for riser card 10 ODD SATA 5 1 CSS LED yellow Global Error LED red 6 VGA connector 2 service LAN connector 7 system LAN connector 2 3 serial connector COM1 8 sys...

Страница 25: ...ot a device without its own boot hard disk via LAN Here Intel PXE is supported The service LAN port serves as management interface and is prepared for RemoteView The Gigabit LAN controller has two LAN connectors The LAN connectors are equipped with two LEDs light emitting diode indicating the transfer rate and the activity Figure 7 LAN connector 1 LAN link activity green on LAN connection off no L...

Страница 26: ...Features 3 8 Settings with jumpers The system board is supplied with all jumpers set on the following positions Figure 8 Jumper default settings JP8 Boot Block JP5 Password Skip 1 2 Normal boot default 2 3 BIOS recovery 1 2 Disable default 2 3 Enable JP5 JP8 ...

Страница 27: ...ced with an identical battery or a battery type recommended by the manufacturer CR2032 Do not throw lithium batteries into the trash can It must be disposed of in accordance with local regulations concerning special waste Make sure that you insert the battery the right way round The plus pole must be on the top Figure 9 Replacing the lithium battery Ê Press the locking spring into direction of the...

Страница 28: ......

Страница 29: ...ons listed here are valid for the described system board ACPI Advanced Configuration and Power Interface ASR R Automatic Server Recovery and Restart ATA Advanced Technology Attachment BBU Battery Backup Unit BIOS Basic Input Output System BMC Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COM COMmunication port CRU Customer Replaceable Unit CSS Customer Self Service C...

Страница 30: ...nagement Interface DMA Direct Memory Access DRAM Dynamic Random Access Memory ECC Error Correction Code EEPROM Electrical Erasable Programmable Read Only Memory EPROM Erasable Programmable Read Only Memory EMRL Embedded RAID Logic ESD Electrostatic Discharge EVRD Enterprise Voltage Regulator Down FBD Fully Buffered DIMM HDD Hard Disk Drive ...

Страница 31: ...ted Mirror Enhanced IOOP Intelligent Organization Of PCI IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface iRMC integrated Remote Management Controller LAN Local Area Network LED Light Emitting Diode MCH Memory Controller Hub MPS Multi Processor Specification NMI Non Maskable Interrupt NOS Network Operating System ...

Страница 32: ... Open Host Controller Interface OS Operating System PCI Peripheral Components Interconnect PDA Prefailure Detection and Analyzing PIO Programmed Input Output PLD Programmable Logic Device POST Power On Self Test PS U Power Supply Unit PWM Puls Wide Modulation PXE Preboot eXecution Environment RAID Redundant Array of Inexpensive Disks ...

Страница 33: ...Clock SAS Serial Attached SCSI SATA Serial ATA SCSI Small Computer Systems Interface SDDC Single Device Data Correction SDRAM Synchronous Dynamic Random Access Memory SHDG Server Hardware Design Guide SHPC Standard Hot Plug Controller SMB System Management Bus SMM Server Management Mode SMP Symmetrically Multi Processing ...

Страница 34: ...S5 Abkürzungen TPM Trusted Platform Module UHCI Unified Host Controller Interface USB Universal Serial Bus VGA Video Graphics Adapter VRD Voltage Regulator Down VRM Voltage Regulator Module WfM Wired for Management WOL Wake up On LAN ...