4. Louver control
4-1. Individual louver control
To independently can be set the airflow pattern of each louver as follows:
This function is given priority to overall louver control. But this function is release during the following
operation.
• Cold air prevention control
• Monitor mode on the auto change over operation
• Defrost operation
The air direction range will change as follows:
Use the wired remote controller to set this function. This function is only available by 2 wire remote
controller.
NOTE:
When the 2 wire remote controller is disconnected, clear the individual setting. Otherwise,
this setting can’t change.
4-2. All louver control
•
All louver operation
When the mode is selected, the standard louver position of the each mode is set.
model name
Operation mode
Standard Position
AUXG36KRLB
Cooling
2
Dry
2
Heating
4
Monitor
2
AUXG45KRLB
AUXG54KRLB
Cooling
2
Dry
2
Heating
3
Monitor
2
NOTES:
• Setting of the wireless remote controller is not displayed on the wired remote controller.
• The setting louver of the individual control function cannot be controlled.
4-1. Individual louver control
- (04-18) -
4. Louver control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS
Содержание AUXG36KRLB
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2020 11 16 SR_CH01_AU015EF_02 ...
Страница 16: ...2 2 Outdoor unit 01 10 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Страница 17: ...2 TECHNICAL DATA AND PARTS LIST 2020 11 16 SR_CH02_AU015EF_02 ...
Страница 47: ...3 TROUBLESHOOTING 2020 06 04 SR_CH03_AU015EF_01 ...
Страница 50: ......
Страница 116: ...5 2 Outdoor unit 03 66 5 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Страница 117: ...4 CONTROL AND FUNCTIONS 2020 06 04 SR_CH04_AU015EF_01 ...
Страница 120: ......
Страница 157: ...5 FILED WORKING 2020 06 04 SR_CH05_AU015EF_01 ...