manualshive.com logo in svg
background image

En-1

1.  SAFETY PRECAUTIONS

To prevent personal injury or property damage, read this section 

carefully before you use this product, and be sure to comply 

with the following safety precautions.

Incorrect operation due to failure to follow the instructions may 

cause harm or damage, the seriousness of which is classified 

as follows:

 WARNING

This mark warns of death or serious injury.

 CAUTION

This mark warns of injury or damage to property.

This mark denotes an action that is PROHIBITED.

This mark denotes an action that is COMPULSORY.

Contents

1.  SAFETY PRECAUTIONS .......................................... 1

2. PREPARATION ......................................................... 2

2.1.  Inserting batteries ............................................. 3

3.  NAME OF PARTS ..................................................... 3

3.1.  Indoor unit ........................................................ 3

3.2.  Remote controller ............................................. 3

4.  BASIC OPERATIONS ............................................... 5

5.  AIRFLOW SETTINGS ............................................... 5

5.1.  Fan speed setting ............................................. 5

5.2.  Airflow direction setting

 .................................... 5

6.  TIMER OPERATIONS ............................................... 5

6.1.   On timer or Off timer

 ......................................... 6

6.2.   Program timer ................................................... 6

6.3.   Sleep timer  ...................................................... 6

7.  ENERGY SAVING OPERATIONS ............................ 6

7.1.  Economy operation .......................................... 6

7.2.  Fan control for energy saving ........................... 6

7.3.  Demand Response ........................................... 6

8.  OTHER OPERATION ................................................ 7

8.1.  Powerful operation ........................................... 7

9.  SETTINGS ON INSTALLATION ................................ 7

9.1.  Remote controller custom code setting ............ 7

10. CLEANING AND CARE ............................................. 7

11. GENERAL INFORMATION ....................................... 8

12. OPTIONAL PARTS ................................................... 9

12.1. Wired remote controller .................................... 9

13. TROUBLESHOOTING .............................................. 9

OPERATION MANUAL

AIR CONDITIONER (Wall Mounted type)

MODEL: 

* Check the model name.

(Refer to the rating label.)

Before using this product, read these instructions thoroughly 

and keep this manual for future reference.

PART No. 9333892030-02

□ ASTH07KNCA

□ ASTH09KNCA

□ ASTH12KNCA

□ ASTH14KNCA

R32

REFRIGERANT

This Air Conditioner contains and 

operates with refrigerant R32.

THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED

BY QUALIFIED PERSONNEL.
Refer to Commonwealth, State, Territory and local legislation,

regulations, codes, installation & operation manuals, before 

the installation, maintenance or service of this product.

9333892030-02_OM_EN.indd   1

9333892030-02_OM_EN.indd   1

01/27/2022   08:35:01

01/27/2022   08:35:01

Содержание ASTH07KNCA

Страница 1: ... Off timer 6 6 2 Program timer 6 6 3 Sleep timer 6 7 ENERGY SAVING OPERATIONS 6 7 1 Economy operation 6 7 2 Fan control for energy saving 6 7 3 Demand Response 6 8 OTHER OPERATION 7 8 1 Powerful operation 7 9 SETTINGS ON INSTALLATION 7 9 1 Remote controller custom code setting 7 10 CLEANING AND CARE 7 11 GENERAL INFORMATION 8 12 OPTIONAL PARTS 9 12 1 Wired remote controller 9 13 TROUBLESHOOTING 9 ...

Страница 2: ...or instruction concerning use of this product by a person responsible for their safety Children should be supervised to ensure that they do not play with this product Dispose of the packing materials safely Tear and dispose of the plastic packing bags so that children cannot play with them There is danger of suffocation if children play with the original plastic bags WARNING Do not start or stop t...

Страница 3: ...re that the intake grille is closed completely Incomplete closing may affect the proper function or performance of the product 2 Indicator lamps light in the following conditions Name Color Operation or condition Operation Green Normal operation Timer Orange Timer operation Economy Green Economy operation 3 2 Remote controller CAUTION To prevent malfunction or damage of the remote controller Place...

Страница 4: ...rflow direction The setting must be done while the setting screen is displayed for each function The button is controllable only when the air conditioner is operating Signal transmitter Aim at the signal receiver of the indoor unit properly Operating range is approximately 7 m will appear when the signal is transmitted The indoor unit will emit a beep when it receives the sig nal properly If there...

Страница 5: ...ouvers by hand Swing operation setting Press to start stop the Swing operation NOTE The Swing operation may stop temporarily when the indoor unit fan is rotating at very low speed or is stopped Airflow direction range Up down airflow direction 1 2 3 4 5 6 Change by Cooling Dry 1 2 3 4 5 6 Heating Fan 1 2 3 4 5 6 Swing operation by Cooling Dry 1 4 Heating 3 6 Fan 1 4 or 3 6 The Swing operation rang...

Страница 6: ... on the indoor unit will blink Blinking pattern and the intervals are as follows Operation mode Indicator lamp blinking pattern Auto Cooling Heating Dry Fan On Blinks 2 times When the DR mode finishes the air conditioner returns to the operation set before entering the DR mode 6 1 On timer or Off timer 1 Select On timer or Off timer in step 1 of Timer setting procedure 2 Each time you press the ti...

Страница 7: ...troller controls When two or more air conditioners are in the room and you wish to operate them separately set the custom code 4 selections possible NOTE If custom codes are different between the indoor unit and the remote controller the indoor unit cannot receive a signal from the remote controller How to set the remote controller custom code 1 Press until the indicators on the remote controller ...

Страница 8: ...ing performance of the product For frost protection an automatic defrost function is equipped in this air conditioner If frost forms the air conditioner will temporarily stop and defrost circuit will operate briefly maximum of 15 minutes indicator on the indoor unit blinks during this operation If frost forms on the outdoor unit after the Heating operation the outdoor unit will stop automatically ...

Страница 9: ...eset the circuit breaker Is the timer operating To check or deactivate the timer setting refer to page 5 Poor cooling or heating performance Is the unit operating under the conditions except the permissible temperature range In this case the air conditioner may stop because of the automatic protection circuit working Do you have an arrangement with your electric company for Demand Response In this...

Страница 10: ... See page Automatic defrosting operation Please wait until finishing the defrosting maximum of 15 minutes 8 Filter indicator Clean the air filter and reset the filter sign 8 Demand response operation 6 Error code display Check the error code and consult authorized service personnel 10 Timer setting error because of Auto restart Reset the clock and timer settings 8 Test run operation for authorized...

Страница 11: ......

Страница 12: ......

Отзывы: