1. Specifications
1-1. Indoor units
Type
Wall mounted
Inverter heat pump
Model name
ASYG30KMTA
ASYG36KMTA
Power supply
230 V ~ 50 Hz
Power supply intake
Outdoor unit
Available voltage range
198—264 V
Capacity
Cooling
Rated
kW
8.0
9.4
Btu/h
27,300
32,100
Min.—Max.
kW
2.9—9.0
2.9—10.0
Btu/h
9,900—30,700
9,900—34,100
Heating
Rated
kW
8.8
10.1
Btu/h
30,000
34,500
Min.—Max.
kW
2.2—11.0
2.7—11.2
Btu/h
7,500—37,500
9,200—38,200
Input power
Cooling
Rated
kW
2.33
3.16
Min.—Max.
0.54—3.86
0.54—4.30
Heating
Rated
2.20
2.73
Min.—Max.
0.48—4.23
0.48—4.30
Fan
HIGH
W
62.0
MED
36.5
LOW
21.0
QUIET
11.5
Current
Cooling
Rated
A
10.2
13.9
Heating
9.7
12.0
EER
Cooling
kW/kW
3.43
2.97
COP
Heating
4.00
3.70
Sensible capacity
Cooling
kW
6.15
6.70
Power factor
Cooling
%
99
Heating
99
Moisture removal
L/h (pints/h)
2.6 (4.6)
3.8 (6.7)
Maximum operating current*
1
Cooling
A
21.0
21.5
Heating
21.0
21.5
Fan
Airflow rate
Cooling
HIGH
m
3
/h
1,330
MED
1,100
LOW
920
QUIET
720
Heating
HIGH
1,330
MED
1,100
LOW
920
QUIET
720
Type × Q'ty
Sirocco fan × 1
Motor output
W
61
Sound pressure level*
2
Cooling
HIGH
dB (A)
50
MED
44
LOW
40
QUIET
33
Heating
HIGH
49
MED
44
LOW
39
QUIET
33
Heat exchanger
Dimensions (H × W × D)
mm
Main: 448 × 900 × 30
Sub1: 84 × 900 × 13.3
Sub2: 126 × 900 × 13.3
Fin pitch
Main: 1.2, Sub: 1.4
Rows × Stages
Main: 3 × 28, Sub1: 1 × 4, Sub2: 1 × 6
Pipe type
Copper tube
Fin type
Aluminum
Enclosure
Material
Polystyrene
Color
White
Approximate color of Munsell N 9.25/
Dimensions
(H × W × D)
Net
mm
340 × 1,150 × 280
Gross
405 × 1,270 × 450
Weight
Net
kg
18.5
Gross
24.5
Connection pipe
Size
Liquid
mm (in)
Ø 9.52 (Ø 3/8)
Gas
Ø 15.88 (Ø 5/8)
Method
Flare
Drain hose
Material
PVC
Size
mm
Ø 13.8 (I.D.), Ø 15.8 to Ø 16.7 (O.D.)
Operation range
Cooling
°C
18 to 32
%RH
80 or less
Heating
°C
16 to 30
Remote controller
Wireless or Mobile app (FGLair*
3
) (Wired [option])
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
– Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
– Pipe length: 5.0 m, Height difference: 0 m. (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *1: Maximum operating current is the total current of the indoor unit and the outdoor unit.
• *2: Sound pressure level:
–
Measured values in manufacturer’s anechoic chamber.
–
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
• *3: Available on Google Play store or on App Store. For details, refer to the setting manual.
1-1. Indoor units
- (01-1) -
1. Specifications
GENERAL
INFORMATION
GENERAL
INFORMATION
Содержание AOYG30KMTA
Страница 3: ...CONTENTS 1 GENERAL INFORMATION 2 TECHNICAL DATA AND PARTS LIST ...
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2019 11 20 SR_CH01_AS019EF_01 ...
Страница 13: ...2 TECHNICAL DATA AND PARTS LIST 2019 11 20 SR_CH02_AS019EF_01 ...
Страница 30: ...8 PC board diagrams 02 16 8 PC board diagrams TECHNICAL DATA AND PARTS LIST TECHNICAL DATA AND PARTS LIST ...