- 134 -
O
U
T
D
OOR UNIT
AOY
G
12-
54LB
13-2. Local setting procedure
NOTE:
Before performing the function setting, be sure to stop the operation of the air conditioner.
Low noise mode
1.
Press the MODE switch button (SW1) for 3 seconds or more to switch to “Local setting mode”.
2.
After confirming the LED lamp of POWER/MODE blinks 9 times, press the ENTER switch
button (SW3).
3.
Press the SELECT switch button (SW2), and adjust the LED lamp as shown below. Then the
LED lamp indicates the current setting.
4.
Press the ENTER switch button (SW3).
5.
Press the SELECT switch button (SW2), and adjust the LED lamps as shown below.
SW1
SW2
SW3
SW4
SW5
(1)
(2)
(3)
(4)
(5)
LED lamps
Switch buttons
POWER
MODE
ERROR
(L1)
(L2)
(L3)
(L4)
(L5)
(L6)
PUMP
DOWN
LOW NOISE
PEAK CUT
Blinks
(9 times
)
Sign “
”: Lights off
(L2)
(L3)
LOW NOISE
Blink
LOW NOISE
MODE
(L2)
(L3)
LOW NOISE
LOW NOISE
MOD
E
Sign “ ”: Lights on
PEAK CUT
MODE 1
MODE 2
Blink
Blink
(L4)
(L5)
(L6)
Содержание AOYG12LBLA
Страница 26: ... 20 DUCT TYPE ARYG12 54LHTBP 5 Wiring diagrams 5 1 Models ARYG12LHTBP ARYG14LHTBP ARYG18LHTBP and ARYG24LHTBP ...
Страница 27: ... 21 DUCT TYPE ARYG12 54LHTBP 5 2 Models ARYG30LHTBP ARYG36LHTBP ARYG45LHTBP and ARYG54LHTBP ...
Страница 110: ... 104 OUTDOOR UNIT AOYG12 54LB 5 Wiring diagrams 5 1 Models AOYG12LBLA and AOYG14LBLA ...
Страница 111: ... 105 OUTDOOR UNIT AOYG12 54LB 5 2 Models AOYG18LBCA and AOYG24LBCA 5 3 Model AOYG30LBTA ...
Страница 112: ... 106 OUTDOOR UNIT AOYG12 54LB 5 4 Model AOYG36LBTA ...
Страница 113: ... 107 OUTDOOR UNIT AOYG12 54LB 5 5 Models AOYG45LBTA and AOYG54LBTA ...