background image

AIR CONDITIONER

Wall mounted type

DESIGN & TECHNICAL MANUAL

INDOOR

ASYG07KPCA

ASYG09KPCA

ASYG12KPCA

OUTDOOR

AOYG07KPCA

AOYG09KPCA

AOYG12KPCA

DR_AS089EF_04

2019.06.19

Содержание AOYG07KPCA

Страница 1: ...AIR CONDITIONER Wall mounted type DESIGN TECHNICAL MANUAL INDOOR ASYG07KPCA ASYG09KPCA ASYG12KPCA OUTDOOR AOYG07KPCA AOYG09KPCA AOYG12KPCA DR_AS089EF_04 2019 06 19 ...

Страница 2: ...roduct specifications and design are subject to change without notice for future improvement For further details please check with our authorized dealer Copyright 2019 Fujitsu General Limited All rights reserved ...

Страница 3: ...ng capacity 8 5 Fan performance 9 5 1 Air velocity distributions 9 5 2 Airflow 11 6 Operation noise sound pressure 13 6 1 Noise level curve 13 6 2 Sound level check point 14 7 Safety devices 15 8 Remote controller 16 8 1 Wireless remote controller 16 9 Function settings 18 9 1 Function settings by using remote controller 18 9 2 Custom code setting for wireless remote controller 22 10 Accessories 2...

Страница 4: ...y compensation rate for pipe length and height difference 33 6 1 Models AOYG07KPCA and AOYG09KPCA 33 6 2 Model AOYG12KPCA 34 7 Additional charge calculation 35 7 1 Models AOYG07KPCA and AOYG09KPCA 35 7 2 Model AOYG12KPCA 35 8 Airflow 36 8 1 Model AOYG07KPCA 36 8 2 Model AOYG09KPCA 36 8 3 Model AOYG12KPCA 37 9 Operation noise sound pressure 38 9 1 Noise level curve 38 9 2 Sound level check point 39...

Страница 5: ...Part 1 INDOOR UNIT WALL MOUNTED TYPE ASYG07KPCA ASYG09KPCA ASYG12KPCA ...

Страница 6: ... 27 Sound pressure level 2 Cooling HIGH dB A 45 45 46 MED 38 38 40 LOW 31 31 33 QUIET 22 22 22 Heating HIGH 45 45 46 MED 40 40 40 LOW 36 36 35 QUIET 26 26 27 Heat exchanger type Dimensions H W D mm 210 600 26 6 Fin pitch 1 3 Rows Stages 2 10 Pipe type Copper tube Fin type Aluminum Enclosure Material Polystyrene Color White Approximate color of Munsell N 9 25 Dimensions H W D Net mm 270 784 224 Gro...

Страница 7: ...2 0 35 C 2 5 35 C 3 4 35 C Heating Average 2 2 10 C 2 4 10 C 2 5 10 C SEER Cooling kWh kWh 6 7 6 7 6 3 SCOP Heating Average 4 0 4 0 4 1 Annual energy consumption QCE kWh a 104 131 189 QHE Average 769 840 853 Sound power level Cooling HIGH dB A 57 58 59 Heating 58 58 59 3 1 Specifications WALL MOUNTED ASYG07 12KPCA WALL MOUNTED ASYG07 12KPCA ...

Страница 8: ... ASYG12KPCA Unit mm 784 224 Outline of indoor unit for pipe inlet Ø65 for pipe inlet Ø65 43 43 292 133 292 67 104 321 48 311 94 84 270 4 2 1 Models ASYG07KPCA ASYG09KPCA and ASYG12KPCA 2 Dimensions WALL MOUNTED ASYG07 12KPCA WALL MOUNTED ASYG07 12KPCA ...

Страница 9: ...ok bracket Outline of the indoor unit 50 or more 67 or more The flare connection part should be installed outdoors 40 or more 30 or more 107 or more 1 500 or more 1 800 or more 163 or more 5 2 1 Models ASYG07KPCA ASYG09KPCA and ASYG12KPCA 2 Dimensions WALL MOUNTED ASYG07 12KPCA WALL MOUNTED ASYG07 12KPCA ...

Страница 10: ...3 Wiring diagrams 3 1 Models ASYG07KPCA ASYG09KPCA and ASYG12KPCA 6 3 1 Models ASYG07KPCA ASYG09KPCA and ASYG12KPCA 3 Wiring diagrams WALL MOUNTED ASYG07 12KPCA WALL MOUNTED ASYG07 12KPCA ...

Страница 11: ... 41 0 34 2 38 1 52 0 34 2 52 1 51 0 34 2 66 1 61 0 34 10 1 84 1 26 0 31 2 05 1 27 0 31 2 12 1 38 0 32 2 26 1 38 0 32 2 33 1 49 0 32 2 47 1 49 0 32 2 61 1 58 0 33 15 2 09 1 21 0 40 2 33 1 21 0 41 2 41 1 32 0 41 2 57 1 32 0 42 2 65 1 43 0 42 2 80 1 43 0 42 2 96 1 52 0 43 20 2 34 1 63 0 50 2 61 1 63 0 51 2 70 1 78 0 51 2 87 1 78 0 51 2 96 1 93 0 52 3 14 1 92 0 52 3 32 2 04 0 53 25 2 22 1 54 0 56 2 48...

Страница 12: ...2 28 0 96 5 7 2 85 0 96 2 78 0 98 2 71 1 00 2 65 1 02 2 58 1 04 0 2 3 33 1 11 3 25 1 14 3 17 1 16 3 09 1 18 3 01 1 21 5 3 3 80 1 27 3 71 1 30 3 62 1 32 3 53 1 35 3 44 1 38 7 6 3 99 1 33 3 90 1 36 3 80 1 39 3 71 1 42 3 61 1 45 10 8 4 13 1 38 4 03 1 41 3 94 1 44 3 84 1 47 3 74 1 50 15 10 4 16 1 39 4 06 1 42 3 96 1 45 3 86 1 48 3 77 1 51 20 15 3 99 1 09 3 90 1 12 3 80 1 14 3 71 1 16 3 61 1 18 24 18 4...

Страница 13: ... louver Up Horizontal airflow direction louver Left Right Unit m s m m 3 2 1 0 1 2 3 0 1 2 3 4 5 6 7 8 2 0 2 0 1 0 1 0 0 5 0 5 Side view Vertical airflow direction louver Up Horizontal airflow direction louver Center m m 3 2 1 0 0 1 2 3 4 5 6 7 8 Unit m s 2 0 0 5 1 0 Side view Vertical airflow direction louver Down Horizontal airflow direction louver Center m m 3 2 1 0 0 1 2 3 4 5 6 7 8 0 5 0 5 2 ...

Страница 14: ...rection louver Left Right Unit m s m m 3 2 1 0 1 2 3 0 1 2 3 4 5 6 7 8 2 0 2 0 1 0 1 0 0 5 0 5 Side view Vertical airflow direction louver Up Horizontal airflow direction louver Center m m 3 2 1 0 0 1 2 3 4 5 6 7 8 Unit m s 2 0 0 5 1 0 Side view Vertical airflow direction louver Down Horizontal airflow direction louver Center m m 3 2 1 0 0 1 2 3 4 5 6 7 8 Unit m s 0 5 0 5 2 0 1 0 10 5 1 Air veloci...

Страница 15: ...h 460 l s 128 CFM 271 LOW m3 h 340 l s 94 CFM 200 QUIET m3 h 240 l s 67 CFM 141 Heating Fan speed Airflow HIGH m3 h 580 l s 161 CFM 341 MED m3 h 460 l s 128 CFM 271 LOW m3 h 380 l s 106 CFM 224 QUIET m3 h 260 l s 72 CFM 153 11 5 2 Airflow 5 Fan performance WALL MOUNTED ASYG07 12KPCA WALL MOUNTED ASYG07 12KPCA ...

Страница 16: ...CFM 288 LOW m3 h 360 l s 100 CFM 212 QUIET m3 h 240 l s 67 CFM 141 Heating Fan speed Airflow HIGH m3 h 630 l s 175 CFM 371 MED m3 h 490 l s 136 CFM 288 LOW m3 h 380 l s 106 CFM 224 QUIET m3 h 260 l s 72 CFM 153 12 5 2 Airflow 5 Fan performance WALL MOUNTED ASYG07 12KPCA WALL MOUNTED ASYG07 12KPCA ...

Страница 17: ...000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HIGH QUIET Model ASYG12KPCA Cooling Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HIGH QUIET Heating Octave band sound pressure level dB 0 dB 0 0002 µbar Octave...

Страница 18: ...crophone Microphone NOTE Detailed shape of the actual indoor unit might be slightly different from the one illustrated above 14 6 2 Sound level check point 6 Operation noise sound pressure WALL MOUNTED ASYG07 12KPCA WALL MOUNTED ASYG07 12KPCA ...

Страница 19: ... ASYG12KPCA Circuit protection Current fuse PCB 250 V 3 15 A Fan motor protection Thermistor protection Activate More than 170 C Fan motor stop Reset 145 C or less Fan motor restart PCB Printed Circuit Board 15 7 Safety devices WALL MOUNTED ASYG07 12KPCA WALL MOUNTED ASYG07 12KPCA ...

Страница 20: ... timer indicator lamp on the indoor unit will begin to flash simultaneously To stop the test operation mode press the START STOP button Then the air conditioner stops the operation k ECONOMY button l POWERFUL button m SET TEMP temperature button Sets desired temperature Sets remote controller custom code n MODE button Switches operation mode AUTO COOL DRY FAN and HEAT Starts ends the remote contro...

Страница 21: ...ller Unit mm Front view Side view Rear view 139 18 56 Top view Size H W D mm 139 56 18 Weight g 70 without batteries 17 8 1 Wireless remote controller 8 Remote controller WALL MOUNTED ASYG07 12KPCA WALL MOUNTED ASYG07 12KPCA ...

Страница 22: ...ustom code Use the following steps to select the custom code of the remote controller Note that the air condi tioner cannot receive a custom code if the air conditioner has not been set for the custom code The custom codes that are set through this process are applicable only to the signal in the function setting For details on how to set the custom codes through the normal process refer to Custom...

Страница 23: ...tted from the indoor unit the START STOP button in the order to confirm the settings 5 Press the RESET button to cancel the function setting mode 6 After completing the function setting be sure to disconnect the power supply and then reconnect it 1 Small is displayed on the right of the custom code during the func tion setting 1 1 Function number Setting value CAUTION After disconnect the power su...

Страница 24: ...Factory setting 11 00 Standard 400 hours 01 Long interval 1 000 hours 02 Short interval 200 hours 03 No indication 2 Room temperature control for indoor unit sensor Depending on the installed environment correction of the room temperature sensor may be re quired Select the appropriate control setting according to the installed environment The temperature correction values show the difference from ...

Страница 25: ...number Setting value Setting description Factory setting 44 00 A 01 B 02 C 03 D 5 Indoor unit fan control for energy saving for cooling Enables or disables the power saving function by controlling the indoor unit fan rotation when the outdoor unit is stopped during cooling operation Function number Setting value Setting description Factory setting 49 00 Disable 01 Enable 00 When the outdoor unit i...

Страница 26: ...e custom code will be changed NOTES If no button is pressed within 30 seconds after the custom code is displayed the system returns to the original clock indicator In this case start again from step 1 The air conditioner custom code is set to prior to shipment To change the custom code con tact your retailer The remote controller resets to custom code when the batteries in the remote controller ar...

Страница 27: ...Part name Exterior Q ty Operating manual 1 Battery 2 Operating manual CD ROM 1 Cloth tape 1 Installation manual 1 Tapping screw 5 Wall hook bracket 1 Remote controller 1 23 10 Accessories WALL MOUNTED ASYG07 12KPCA WALL MOUNTED ASYG07 12KPCA ...

Страница 28: ...er UTZ RXLA Wall or pillar mountable and holds the wireless remote controller Wireless LAN adapter UTY TFSXF2 Remotely manage an air conditioning system using mobile devices such as smartphones and tablets 24 11 1 Others 11 Optional parts WALL MOUNTED ASYG07 12KPCA WALL MOUNTED ASYG07 12KPCA ...

Страница 29: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOYG07KPCA AOYG09KPCA AOYG12KPCA ...

Страница 30: ...lor Beige Approximate color of Munsell 10YR 7 5 1 0 Dimensions H W D Net mm 541 663 290 Gross 596 798 369 Weight Net kg 23 25 Gross 25 27 Connection pipe Size Liquid mm in Ø 6 35 1 4 Gas Ø 9 52 3 8 Method Flare Pre charge length m 15 Max length 20 Max height difference 15 Operation range Cooling C 10 to 46 Heating 15 to 24 Drain hose Material PP Size mm Ø 13 0 I D Ø 16 0 to Ø 16 8 O D NOTES Specif...

Страница 31: ...330 Pitch of bolts for installation 4 M10 hole Bottom view Side view Valve part Top view Side view Side view Front view Pitch of bolts for installation 353 541 20 184 120 37 170 331 Drain port Ø42 27 2 1 Models AOYG07KPCA AOYG09KPCA and AOYG12KPCA 2 Dimensions OUTDOOR UNIT AOYG07 12KPCA OUTDOOR UNIT AOYG07 12KPCA ...

Страница 32: ...ation When the upper space is open Unit mm Obstacles at rear only Obstacles at rear and sides 100 or more 250 or more 100 or more 100 or more Obstacles at front Obstacles at front and rear 600 or more 600 or more 100 or more When there is an obstruction in the upper space Unit mm Obstacles at rear and above Obstacles at rear sides and above 100 or more Max 200 600 or more 250 or more 100 or more M...

Страница 33: ... the following ex ample When an obstruction in the upper space When the upper space is open Unit mm Obstacles at rear only Obstacles at front only 200 or more 250 or more 1 000 or more 250 or more Obstacles at front and rear 200 or more 1 000 or more 250 or more When an obstruction in the upper space Unit mm Obstacles at rear and above 1 500 or more 200 or more 250 or more 250 or more Max 300 1 50...

Страница 34: ...age where the drain water could freeze Otherwise the drainage from the upper unit may form ice and cause a malfunction of the lower unit When the outdoor temperature is 0 C or less do not use the accessory drain pipe and drain cap If the drain pipe and drain cap are used the drain water in the pipe may freeze in extremely cold climate For reverse cycle model only In area with heavy snowfall if the...

Страница 35: ...R OUTDOOR Compressor Cooling Heating ThD ThR ThPI ThO ThHO Thermistor Discharge temperature Thermistor Outdoor temperature Thermistor Heat exchanger out temperature ThD ThO ThHO Thermistor Room temperature Thermistor Pipe temperature ThR ThPI Muffler 31 4 1 Models AOYG07KPCA AOYG09KPCA and AOYG12KPCA 4 Refrigerant circuit OUTDOOR UNIT AOYG07 12KPCA OUTDOOR UNIT AOYG07 12KPCA ...

Страница 36: ...5 Wiring diagrams 5 1 Models AOYG07KPCA AOYG09KPCA and AOYG12KPCA 32 5 1 Models AOYG07KPCA AOYG09KPCA and AOYG12KPCA 5 Wiring diagrams OUTDOOR UNIT AOYG07 12KPCA OUTDOOR UNIT AOYG07 12KPCA ...

Страница 37: ...0 929 5 0 992 0 983 0 969 0 893 0 933 0 1 000 0 991 0 976 0 901 0 940 Indoor unit is lower than outdoor unit 2 5 1 000 0 991 0 976 0 901 0 940 7 5 0 991 0 976 0 901 0 940 10 0 976 0 901 0 940 15 0 901 0 940 HEATING Pipe length m 5 7 5 10 15 20 Height difference H m Indoor unit is higher than outdoor unit 1 15 0 832 0 822 10 0 917 0 832 0 822 7 5 0 961 0 917 0 832 0 822 5 1 000 0 961 0 917 0 832 0 ...

Страница 38: ...44 0 887 0 896 7 5 0 972 0 944 0 887 0 896 10 0 944 0 887 0 896 15 0 887 0 896 HEATING Pipe length m 5 7 5 10 15 20 Height difference H m Indoor unit is higher than outdoor unit 1 15 0 896 0 879 10 0 968 0 890 0 879 7 5 0 994 0 968 0 896 0 879 5 1 000 0 994 0 968 0 896 0 879 0 1 000 0 994 0 968 0 896 0 879 Indoor unit is lower than outdoor unit 2 5 0 995 0 989 0 963 0 891 0 875 7 5 0 987 0 961 0 8...

Страница 39: ...e length m 15 or less 20 Max 20 g m Additional charge g 0 100 7 2 Model AOYG12KPCA Refrigerant type R32 Refrigerant amount g 590 Refrigerant charge Total pipe length m 15 or less 20 Max 20 g m Additional charge g 0 100 35 7 1 Models AOYG07KPCA and AOYG09KPCA 7 Additional charge calculation OUTDOOR UNIT AOYG07 12KPCA OUTDOOR UNIT AOYG07 12KPCA ...

Страница 40: ...50 l s 458 CFM 971 Heating Airflow m3 h 1 450 l s 403 CFM 853 8 2 Model AOYG09KPCA Cooling Airflow m3 h 1 650 l s 458 CFM 971 Heating Airflow m3 h 1 450 l s 403 CFM 853 36 8 1 Model AOYG07KPCA 8 Airflow OUTDOOR UNIT AOYG07 12KPCA OUTDOOR UNIT AOYG07 12KPCA ...

Страница 41: ...8 3 Model AOYG12KPCA Cooling Airflow m3 h 1 700 l s 472 CFM 1 001 Heating Airflow m3 h 1 470 l s 408 CFM 865 37 8 3 Model AOYG12KPCA 8 Airflow OUTDOOR UNIT AOYG07 12KPCA OUTDOOR UNIT AOYG07 12KPCA ...

Страница 42: ...ncy Hz NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Model AOYG09KPCA Cooling 0 10 20 30 40 50 60 70 80 63 125 250 500 1 000 2 000 4 000 8 000 Octave band sound pressure level dB 0 dB 0 0002 μbar Octave band center frequency Hz NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Heating 0 10 20 30 40 50 60 70 80 63 125 250 500 1 000 2 000 4 000 8 000 Octave band s...

Страница 43: ...50 500 1 000 2 000 4 000 8 000 Octave band sound pressure level dB 0 dB 0 0002 μbar Octave band center frequency Hz NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 9 2 Sound level check point 1 m Microphone Microphone Rear Airflow Rear view Side view NOTE Detailed shape of the actual outdoor unit might be slightly different from the one illustrated above 39 9 1 Noise level curve ...

Страница 44: ...ength m 21 1 Maximum operating current is the total current of the indoor unit and the outdoor unit 2 Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005 As the regulations of wire size and circuit breaker differ in each country or region select appropriate de vices complied to the regional standard 3 Limit voltage drop to less than 2 If voltage drop is 2 or more in...

Страница 45: ... 122 C Fan motor stop Reset 77 114 C Fan motor restart Compressor protection Terminal protection program Discharge temp Activate 110 C Compressor stop Reset After 7 minutes Compressor restart Thermal protection program Outdoor temp Activate COOL or DRY 15 C HEAT 20 C Compressor stop Reset COOL or DRY 10 C HEAT 15 C Compressor restart 41 11 Safety devices OUTDOOR UNIT AOYG07 12KPCA OUTDOOR UNIT AOY...

Страница 46: ...dels AOYG07KPCA AOYG09KPCA and AOYG12KPCA Part name Exterior Q ty Part name Exterior Q ty Drain pipe 1 42 12 1 Models AOYG07KPCA AOYG09KPCA and AOYG12KPCA 12 Accessories OUTDOOR UNIT AOYG07 12KPCA OUTDOOR UNIT AOYG07 12KPCA ...