8-3. Current release control
The rotation number of compressor is controlled so that the outdoor unit input current does not ex-
ceeds current limit value set according to the outdoor temperature.
The rotation number of compressor returns according to the operation mode, when the current be-
comes lower than the release value.
¢
AOUH18LMAS1
Operation mode
Outdoor temp. (Ta)
Trigger condition Release condition
Cooling
125.6 °F (52 °C) ≤ Ta
8.0 A
7.5 A
122.0 °F (50 °C) ≤ Ta < 125.6 °F (52 °C)
10.0 A
9.5 A
Ta < 122.0 °F (50 °C)
12.5 A
12.0 A
Heating
60.8 °F (16 °C) ≤ Ta
10.0 A
9.5 A
53.6 °F (12 °C) ≤ Ta < 60.8 °F (16 °C)
11.5 A
11.0 A
Ta < 53.6 °F (12 °C)
13.0 A
12.5 A
¢
AOUH24LMAS1
Operation mode
Outdoor temp. (Ta)
Trigger condition Release condition
Cooling
125.6 °F (52 °C) ≤ Ta
8.0 A
7.5 A
122.0 °F (50 °C) ≤ Ta < 125.6 °F (52 °C)
10.0 A
9.5 A
114.8 °F (46 °C) ≤ Ta < 122.0 °F (50 °C)
13.0 A
12.5 A
107.6 °F (42 °C) ≤ Ta < 114.8 °F (46 °C)
14.0 A
13.5 A
Ta < 107.6 °F (42 °C)
14.5 A
14.0 A
Heating
68.0 °F (20 °C) ≤ Ta
11.0 A
10.5 A
60.8 °F (16 °C) ≤ Ta < 68.0 °F (20 °C)
13.0 A
12.5 A
Ta < 60.8 °F (16 °C)
15.0 A
14.5 A
8-4. Compressor temperature protection
→hen the compressor temperature sensor detects higher than the trigger condition below, the com-
pressor is stopped. →hen the compressor temperature sensor detects the release condition, the pro-
tection is released.
Trigger condition
226.4°F (108°C)
Release condition
176.0°F (80°C)
(3 minutes after compressor stop)
8-5. High pressure protection
Trigger condition
Pressure switch: Off (Open: Higher than 4.2 MPa)
Compressor stop
Release condition
Pressure switch: On (Close: Lower than 3.2 MPa)
(3 minutes after compressor stop)
Compressor restart
8-3. Current release control
- (04-32) -
8. Various protections
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
Содержание AOUH18LMAS1
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2021 11 01 SR_CH01_AS052EF_01 ...
Страница 15: ...2 TECHNICAL DATA AND PARTS LIST 2021 11 17 SR_CH02_AS052EF_04 ...
Страница 39: ...3 TROUBLESHOOTING 2021 11 17 SR_CH03_AS052EF_01 ...
Страница 42: ......
Страница 135: ...4 CONTROL AND FUNCTIONS 2021 11 17 SR_CH04_AS052EF_01 ...
Страница 138: ......
Страница 173: ...5 FILED WORKING 2021 11 17 SR_CH05_AS052EF_01 ...