7. Safety devices
Type of
protection
Protection form
Model
ASHG07KETA
ASHG07KETA-B
ASHG09KETA
ASHG09KETA-B
ASHG12KETA
ASHG12KETA-B
Circuit
protection
Current fuse (PCB*)
250 V, 3.15 A
Fan motor
protection
Thermistor protection
Activate
More than 85 °C
Fan motor speed down
Reset
85 °C or less
Fan motor speed recover
Type of
protection
Protection form
Model
ASHG14KETA
ASHG14KETA-B
Circuit
protection
Current fuse (PCB*)
250 V, 3.15 A
Fan motor
protection
Power IC thermal
shutdown protection
Activate
125±25 °C
Fan motor stop
Reset
110
+25
-20
°C
Fan motor restart
*PCB: Printed Circuit Board