En-8
SPECIFICATIONS
AUXB07L
AUXB09L
AUXB12L
AUXB14L
AUXB18L
230 V~50 Hz
198 to 264 V
2.20
2.80
3.60
4.00
5.00
2.50
3.20
4.10
4.50
5.45
230
570
570
18
MODEL
POWER SOURCE
AVAILABLE VOLTAGE RANGE
COOLING CAPACITY
[kW]
HEATING CAPACITY
[kW]
DIMENSIONS & WEIGHT
HEIGHT
[mm]
WIDTH
[mm]
DEPTH
[mm]
WEIGHT
[kg]
AU A20L
AU A25L
AU A30L
230 V~50 Hz
198 to 264 V
5.70
7.05
8.80
5.80
7.85
9.10
246
830
830
34
MODEL
POWER SOURCE
AVAILABLE VOLTAGE RANGE
COOLING CAPACITY
[kW]
HEATING CAPACITY
[kW]
DIMENSIONS & WEIGHT
HEIGHT
[mm]
WIDTH
[mm]
DEPTH
[mm]
WEIGHT
[kg]
AU A36L
AU A45L
AU A54L
230 V~50 Hz
198 to 264 V
10.5
12.7
14.1
12.7
13.7
15.8
296
830
830
40
MODEL
POWER SOURCE
AVAILABLE VOLTAGE RANGE
COOLING CAPACITY
[kW]
HEATING CAPACITY
[kW]
DIMENSIONS & WEIGHT
HEIGHT
[mm]
WIDTH
[mm]
DEPTH
[mm]
WEIGHT
[kg]
●
Acoustic Noise Information : The maximum sound pressure level is less than 70 dB (A) for both indoor unit and outdoor
unit.
According to IEC 704-1 and ISO 3744.
The following conditions may not be breakdowns so check again.
Symptom
Doesn’t operate at all:
The operation mode
cannot be changed:
Poor Cooling
(or Heating)
performance:
See page
—
—
—
4
4
4
—
5
—
—
—
—
—
Items to check
●
Has there been a power failure?
●
Has a fuse blown out, or a circuit breaker been tripped?
●
Is the main power switch set to the OFF position?
●
Are you trying to engage in an operation different from the priority state?
●
Is it in standby state?
●
Are you trying to change to an operation different from the priority conditions?
●
Did you adjust the room temperature settings (thermostat) correctly?
●
Is the air filter dirty?
●
Are the air conditioner’s inlet port or outlet port blocked?
●
Is there a window or door open?
●
In the case of Cooling operation, is a window allowing bright sunlight to enter?
(Close the curtains.)
●
In the case of Cooling operation, are there heating apparatus and computers
inside the room, or are there too many people in the room?
●
Is the fan speed set to low?
In the following situations stop operation immediately and get in touch with authorized
service personnel.
●
The problem cannot be solved even when the troubleshooting checks have been performed.
●
The OPERATION indicator lamp (red) is flashing very fast.
●
The wired remote controller or simple remote controller indicate EE (when connected).
●
It has burning smell.
9369313028_OM_en.p65
29/8/06, 15:46
8