4-12
SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007
7. Check the status of the move-destination domain and moved system board.
Execute the
showdcl
(8) command to check the operation status of the move-
destination domain, and then execute the
showboards
(8) command to check the
status of the moved system board.
4.5
Examples: Replacing a System Board
This section provides examples of operations to replace a system board in a domain.
The examples illustrate replacement of a system board in a Uni-XSB environment
and a system board in a Quad-XSB environment. In each sample operation, a
procedure conforming to
Section 4.1.4, “Flow: Replacing a System Board” on
, is used, and the system board shown in each figure is replaced using the
XSCF shell.
Note –
You cannot use DR to replace a system board in a midrange server because
replacing a system board replaces an MBU. To replace a system board in a midrange
server, you must turn off the power for all domains, then perform a hardware
replacement.
XSCF>
showdcl -d 1
DID
LSB
XSB
Status
01
Running
00
01-0
01
00-1
XSCF>
showboards 00-1
XSB
DID(LSB)
Assignment
Pwr
Conn
Conf
Test
Fault
-------------------------------------------------------------------
00-1
01(01)
Assigned
y
y
y
Passed
Normal
Содержание SPARC Enterprise M4000
Страница 1: ...Dynamic Reconfiguration DR User s Guide SPARC Enterprise M4000 M5000 M8000 M9000 Servers English ...
Страница 2: ......
Страница 6: ......
Страница 23: ...Preface xxi Reader s Comment Form ...
Страница 90: ...3 28 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User s Guide September 2007 ...
Страница 116: ...4 26 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User s Guide September 2007 ...
Страница 152: ...A 36 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User s Guide September 2007 ...
Страница 158: ...Glossary 4 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User s Guide September 2007 ...
Страница 161: ......