![Fujitsu Siemens Computers Primergy RX220 Скачать руководство пользователя страница 32](http://html.mh-extra.com/html/fujitsu-siemens-computers/primergy-rx220/primergy-rx220_service-supplement-manual_2344452032.webp)
32
Service Supplement
RX220
Replacing the internal server power supply cable
Replacement routines
Figure 19: Removing the line filter
Ê
Press down the two edges of the line filter’s stop spring (both at the top (1)
and at the bottom (2)).
I
To permit access to the stop spring on the underside of the line filter
access holes are provided both at the side and on the underside of
the server housing.
Ê
Now push the line filter out at the rear through the opening in the housing.
Ê
Push the line filter in at the rear through the opening in the housing.
Ê
Insert the internal power cable into the cable clamp and close the cable
clamp.
Ê
Close the server and connect all power plugs (for a detailed description see
the Options Guide).
1
2