Chapter
Overview of Monitor Parameters (Ch5)
The monitor allows you to verify the current input and output conditions of the controller.
The monitor can display the following items.
These parameters are displayed only. The settings cannot be changed in these parameters.
Note 1: Displays when the sixth digit is A, C, E, or P. (Standard type only).
Note 2: Displays when the fifth digit of the model number is V.
Note 3: Displays when the seventh number of the model number is H, K, E, or 2, or the eleventh digit is D (RSV included).
Note 4: Displays when the seventh number of the model number is G or J, or the eleventh digit is A (CT included).
Note 5: Displays depending on the ninth digit and eleventh digit of the model code.
Note 6: The parameters in the shaded area indicates the industrial values.
Display
Parameter name
Function
range
Remarks
Page
"
STAT
" (STAT)
Ramp/soak
progress
Displays the progress of the ramp/soak
oFF (ramp/soak is stopped)
1-rP (Step 1 Ramp)
1-Sk (Step 1 Soak)
16rP (Step 16 Ramp)
16Sk (Step 16 Soak)
End (ramp/soak is finished)
65
"
Mv1
" (Mv1)
Control Output
Display (MV1)
Displays the output value of the control
output (OUT1).
-3.0% to 103.0%
65
"
Mv2
" (Mv2)
Control Output
Display (MV2)
Displays the output value of the control
output (OUT2) (during dual control).
-3.0% to 103.0%
Note 1
"
PFb
" (PFb)
PFB Input Value
Display
Displays the input value of the position
feedback
-3.0% to 103.0%
Note 2
66
"
rSv
"(rSv)
RSV Input Value
Display
Displays the input value for RSV.
-5% to 105% FS
Note 3
66
"
CT1
" (CT1)
Heater current
Displays the heater current
0A, 0.4A to 50.0A
Note 4
67
"
LC1
" (LC1)
Leak current
Displays the leak current
0A, 0.4A to 50.0A
Note 4
67
"
TM1
" (TM1)
Remaining time on
timer 1
Displays the remaining time on timer 1
0 sec to 9999 sec / 0 min to 9999 min
Note 5
68
"
TM2
" (TM2)
Remaining time on
timer 2
Displays the remaining time on timer 2
0 sec to 9999 sec / 0 min to 9999 min
Note 5
"
TM3
" (TM3)
Remaining time on
timer 3
Displays the remaining time on timer 3
0 sec to 9999 sec / 0 min to 9999 min
Note 5
"
TM4
" (TM4)
Remaining time on
timer 4
Displays the remaining time on timer 4
0 sec to 9999 sec / 0 min to 9999 min
Note 5
"
TM5
" (TM5)
Remaining time on
timer 5
Displays the remaining time on timer 5
0 sec to 9999 sec / 0 min to 9999 min
Note 5
"
FALT
" (FALT)
Error source display
Displays the source of an error
68
"
PLno
"(PLno)
Current palette No.
Displays the PID palette No. currently
selected.
0 to 7
69
"
PTno
"(PTno)
Current pattern No.
Displays the pattern No. of the ramp
soak currently selected.
0 to 6
69
...
0bit :PFB input underflow
1bit :PFB input overflow
8bit : PV input underflow
9bit : PV input overflow
10bit: underrange
11bit: overrange
12bit: RSV underrange
13bit: RSV overrange
14bit: range setting error
15bit: EEPROM error
FALT
=□□
0
□
Содержание PXG4
Страница 1: ...c...
Страница 10: ...9 1 Chapter Chapter 1 Part Names and Functions Part Names and Functions 10...
Страница 21: ...20 MEMO 2 Chapter...
Страница 43: ...42 MEMO 4 Chapter...
Страница 53: ...52 MEMO 5 Chapter...
Страница 71: ...70 MEMO 7 Chapter...
Страница 89: ...88 MEMO 8 Chapter...
Страница 106: ...105 9 Chapter Behavior when control is lost Limit Cycle PV SV Time tuning MV control lost 100...
Страница 119: ...118 MEMO 10 Chapter...
Страница 125: ...124 MEMO 11 Chapter...
Страница 131: ...130 MEMO 12 Chapter...
Страница 132: ...131 13 Chapter Chapter 13 Password Setup Ch11 Overview of Password Setup Ch11 132 Passwords 1 to 3 132...
Страница 141: ...140 MEMO 14 Chapter...
Страница 151: ...150 MEMO 15 Chapter...
Страница 152: ...151 16 Chapter Chapter 16 Troubleshooting Troubleshooting 152...
Страница 154: ...153 17 Chapter Chapter 17 Appendix Delay Start Function 154 Return to Factory Default Setting Function 155...
Страница 157: ...156 MEMO 17 Chapter...